Jacuzzi J-280 User Manual

Page of 64
J-200
6.0  power requirements
Jacuzzi spas are designed to provide optimum performance and 
flexibility of use when connected to the maximum electrical service listed 
below. Minor circuit board modifications can be performed to allow your 
new spa to accept an electrical service other than the factory operation 
setting. 
contact your authorized Jacuzzi dealer.
all north american J-270 and J-280 models (60 Hz)
240V/40A*
240V/50A**
240V/60A***
Circuit Breaker (2-Pole):
40A
*
50A
**
60A
***
Number of Wires:
3
3
3
Frequency:
60 Hz
60 Hz
60 Hz
Current Draw:
26A
36A
45A
*  In 40A configuration, the heater will not operate while either jets 
pump is running in high speed. Note: pump 2 runs only in high 
speed.
**  In 50A configuration, the heater will not operate while both jets 
pumps are running in high speed. This is the factory setting. 
Note: pump 2 runs only in high speed.
***  In 60A configuration the heater will operate while both jets pumps 
are running in high speed.
all north american J-230 models (60 Hz)
240V/40A*
240V/50A**
Circuit Breaker (2-Pole):
40A
*
50A
**
Number of Wires:
3
3
Frequency:
60 Hz
60 Hz
Current Draw:
26A
36A
*  In 40A configuration, the heater will not operate while the jets 
pump is running in high speed.
**  In 50A configuration, the heater will operate while the jets pump is 
running in high speed. This is the factory setting. 
13