4. If you intend to configure the MultiVOIP remotely using the 
MultiVOIP Windows GUI, connect an RJ-11 phone cable between the 
Command Modem connector (at the rear of the MultiVOIP) and a 
receptacle served by a telco POTS line.  See Figure 3-6.   
The Command Modem is built into the MultiVOIP unit.  To configure 
the MultiVOIP remotely using its Windows GUI, you must call into 
the MultiVOIP’s Command Modem.  Once a connection is made, the 
configuration process is identical to local configuration with the 
Windows GUI. 
ETHERNET COMMAND
DIGITAL VOICE
ETHERNET COMMAND
10 BASET
RS232
DIGITAL VOICE
TRUNK
COMMAND
MODEM
Telco POTS Line
Grounding Screw
 
Figure 3-6. MVP-2410/3010 Voip Connections  
                     for GND & Remote Config Modem 
5. Ensure that the unit is properly connected to earth ground by 
verifying that it is reliably grounded when mounted within a rack.  
This can be accomplished by connecting a grounding wire between 
the chassis grounding screw (see Figure 3-6) and a metallic object that 
will provide an electrical ground. 
6. Turn on power to the MultiVOIP by setting the power switch on the 
right side panel to the ON position.  Wait for the Boot LED on the 
MultiVOIP to go off before proceeding.  This may take a couple of 
minutes. 
Proceed to Chapter 4 “Software Installation.”