Fujitsu PRIMERGY RX300 S5 VFY:R3005SF010NL Leaflet

Product codes
VFY:R3005SF010NL
Page of 2
ENERGY STAR Power and Performance Data Sheet
PRIMERGY RX300 S5; LKN:R3005S0021IN
Benchmark Used and Type of Workload
Avg. Power Measured During Benchmark Run
Benchmark Performance Score
Power Performance Ratio
 (perf score/avg. power)
Link to Full Benchmark Report (Where Available)
Benchmark Used and Type of Workload
Avg. Power Measured During Benchmark Run
Benchmark Performance Score
Power Performance Ratio
 (perf score/avg. power)
Link to Full Benchmark Report (Where Available)
Enabled on 
Shipment
End-User Enabling 
Required
Processor Dynamic Voltage and Frequency Scaling
x
Processor or Core Reduced Power States 
x
Power Capping
x
x
Low Power Memory States
Low Power I/O States
Liquid Cooling Capability
Other1:
Other2:
SiSoftware Sandra Engineer 2009.SP3c, .Net Multimedia, Double x1
51,27Mpixel/s
0.20Mpixel/s / W
262,6W
Page 2 of 2
Power and Performance for Benchmark #1
Variable Speed Fan Control Based on Power or Thermal Readings
Ben
ch
mark #2
Power Saving Features
Ben
ch
mark #1
Power and Performance for Benchmark #2 (optional)
N/A
Other2:
Other3:
Other4:
Input Power Available & Accuracy?
Input Air Temp Available & Accuracy?
Processor Utilization Available?  
Other Data Measurements Available & Accuracy?
Compatible Protocols for Data Collection 
Averaging method and time period
Minimum
Typical
Maximum
Reference Configurations
2xX5550;
6x2GB, PC3-10600R; 
1x120GB, 5400 RPM 
SATA;
2x800W PSU
Total Power Dissipation (watts)
235
Delta Temperature at Exhaust at Peak Temp. (˚C)
11
Airflow at Maximum Fan Speed (CFM) at Peak Temp.
135m
3
/h
Airflow at Nominal Fan Speed (CFM) at Nominal Temp.
70m
3
/h
Linear Average calculation / 5 sec.
IPMI
Yes, +10% above 200W and +25% until 200W
Yes
Power and Temperature Measurement and Reporting
Thermal Information
*
*
  Thermal information is provided for the minimum, typical and maximum configurations for the model line
   References: ASHRAE Extended Environmental Envelope Final August 1, 2008
                     Thermal Guidelines for Data Processing Environments, ASHRAE, 2004, ISBN 1-931862-43-5
                     Peak temperature is defined as 35 ˚C, Nominal Temperature is defined as 18 - 27 ˚C
Notes
1.  Benchmark results stated above reflect results published on 08/07/2009.
Yes, +/- 3°C