GE js998skss Specification Guide

Page of 2
For answers to your Monogram,
® 
GE Profile
 or  
GE
®
 appliance questions, visit our website at 
ge.com or call GE Answer Center
®
 service,  
800.626.2000.
JS998SK 
GE Profile
™ 
30" Slide-In Electric Range with Trivection
 Technology
Specification Revised 7/09
220454
All GE ranges are equipped with 
an Anti-Tip device. The installation 
of this device is an important, 
required step in the installation  
of the range.
Listed by 
Underwriters 
Laboratories
Dimensions and Installation Information (in inches) 
Note: Cabinets installed adjacent to slide-in ranges must have an adhesion 
spec of at least 194° temperature rating. 
Note: To reduce the possibility of scorching the side walls above the countertop 
when no load is present on burners, it is recommended that a minimum 6” 
spacing from adjacent side wall be allowed for possible extended high-heat 
element operation.
Receptacle Locations: For all 30" Slide-In Ranges locally approved flexible 
service cord or conduit must be used because terminals are not accessible 
after range installation. See shaded area in drawing for location of electrical 
outlet box. Recommended outlet locations allow range to be installed directly against rear wall. 
KW Rating
240V 12.8
208V 8.7
Breaker Size
240V 40 Amps
208V 40 Amps
Installation information: Before installing, consult installation instructions 
packed with product for current dimensional data. 
Optional Kits For Slide-In 
Electric Ranges 
(Available At Additional Cost)
Accessory Backguards 
(Attaches to the back of range 
as a backguard when unit is 
installed in 30" free-standing 
cutout) 
JXS32SS (Stainless) - 4" High 
JXS32WW (White) - 4" High 
JXS32BB (Black) - 4" High 
JXS37WW (White) - 5-1/4" High 
JXS37CC (Bisque) - 5-1/4" High 
JXS37BB (Black) - 5-1/4" High
Body Sides 
(Slide-in ranges are sold  
without sides installed. Can 
be installed on either left 
or right when unit has one 
exposed side [no cabinet 
adjacent]. Kit contains  
1 body side) 
JXS77WW (White) 
JXS77BB (Black) 
Rear Filler Strip 
WB07T10680 - Black Filler 
Strip Assembly 
Optional Lower Trim Kits 
(If counter height is greater 
than 36.5", a lower trim kit 
is recommended to extend 
the useful height to 38" 
maximum)
 
JXS56WW – White 
JXS56BB – Black
28-1/4*
36
Maintain 
at least 6" 
from nearest 
combustible 
surface.
Acceptable
Electrical
Outlet Area
30" Slide-In Range 
Dimensions (in inches)
45-1/8
2-1/4
5
6
4-1/2
30
30" Min.
15" Min.
6
30" Slide-in Elec. Range 
Aug. 8, 2003 -km
23-3/16
30
30
If you are NOT using the
Filler strip or Backguard:
If you are using the
Filler strip or Backguard:
25
*Wall to front of 
 closed door handle 
on model JSP34.
 28" on models 
 JSP26/JSS26/16.
Note: Range may be placed with 0" clearance (flush) at the back wall and side walls 
below countertop if the range side trims above the countertop extend beyond the cabinet 
fronts at least 1/4". (Self-clean models only.) Maintain at least 6" distance from nearest 
combustible surface.    
30
31-1/2
28-1/4*
36
Maintain 
at least 6" 
from nearest 
combustible 
surface.
Acceptable
Electrical
Outlet Area
30" Slide-In Range 
Dimensions (in inches)
45-1/8
2-1/4
5
6
4-1/2
30
30" Min.
15" Min.
6
30" Slide-in Elec. Range 
Aug. 8, 2003 -km
23-3/16
30
30
If you are NOT using the
Filler strip or Backguard:
If you are using the
Filler strip or Backguard:
25
*Wall to front of 
 closed door handle 
on model JSP34.
 28" on models 
 JSP26/JSS26/16.
Note: Range may be placed with 0" clearance (flush) at the back wall and side walls 
below countertop if the range side trims above the countertop extend beyond the cabinet 
fronts at least 1/4". (Self-clean models only.) Maintain at least 6" distance from nearest 
combustible surface.    
30
31-1/2
Acceptable
Electrical
Outlet Area
30" Min.
30" Min.
Shave Raised Edge To Clear
31-1/8" Wide Control Panel
Excluding Models JSS28 and JSP39 
2-7/8" 
To Front 
Surface Of 
Countertop
20-5/8" Door 
Clearance
From Front 
Surface of 
Countertop
31-1/4
30
25-3/4**
Recommended
6" Min.
From Walls
23-3/16
15" Min.
A/B*
13" Max.
2-1/2
30
25
9/16
7-1/2
2-1/2
Accessory
Backguard
24
36-1/4
*JXS37 is 5-1/4" and JXS32 is 4"
 
(excluding handle)
**Total depth from wall to 
front of closed oven door 
including handle is 27-13/16.
35-7/8"–38"
from floor to
countertop
If the countertop area is not flat, excess tension may be applied to the glass cooktop causing breakage 
and voiding the warranty. Make sure the wall covering, countertop, flooring and cabinets around the range
can withstand the heat (up to 200˚F) generated by the range.
A. Allow 30" minimum clearance between surface units and bottom of unprotected wood or metal cabinet, 
or allow a 24" minimum when bottom of wood or metal cabinet is protected by no less then 1/4" thick
flame retardant millboard covered with no less than No. 28 MSG sheet metal (.015
" thick), .015" thick
stainless steel, .025
" aluminum or .020" copper.
B. This appliance has been approved for 0" spacing to adjacent surfaces above the cooktop. However, 
a minimum 6
" spacing to surfaces less than 15" above the cooktop and adjacent cabinetry 
is recommended to reduce exposure to steam, grease splatter and heat. Allow 1/4
" minimum clearance 
at the back wall.
To reduce the risk of burns or fire when reaching over hot surface elements, cabinet storage space above
the cooktop should be avoided. If cabinet storage space is to be provided above the cooktop, the risk can 
be reduced by installing a range hood that projects at least 5" beyond the front of the cabinets. Cabinets
installed above the cooktop must be no deeper than 13".
Acceptable
Electrical
Outlet Area
30" Min.
30" Min.
Shave Raised Edge To Clear
31-1/8" Wide Control Panel
Excluding Models JSS28 and JSP39 
2-7/8" 
To Front 
Surface Of 
Countertop
20-5/8" Door 
Clearance
From Front 
Surface of 
Countertop
31-1/4
30
25-3/4**
Recommended
6" Min.
From Walls
23-3/16
15" Min.
A/B*
13" Max.
2-1/2
30
25
9/16
7-1/2
2-1/2
Accessory
Backguard
24
36-1/4
*JXS37 is 5-1/4" and JXS32 is 4"
 
(excluding handle)
**Total depth from wall to 
front of closed oven door 
including handle is 27-13/16.
35-7/8"–38"
from floor to
countertop
If the countertop area is not flat, excess tension may be applied to the glass cooktop causing breakage 
and voiding the warranty. Make sure the wall covering, countertop, flooring and cabinets around the range
can withstand the heat (up to 200˚F) generated by the range.
A. Allow 30" minimum clearance between surface units and bottom of unprotected wood or metal cabinet, 
or allow a 24" minimum when bottom of wood or metal cabinet is protected by no less then 1/4" thick
flame retardant millboard covered with no less than No. 28 MSG sheet metal (.015" thick), .015" thick
stainless steel, .025" aluminum or .020" copper.
B. This appliance has been approved for 0" spacing to adjacent surfaces above the cooktop. However, 
a minimum 6" spacing to surfaces less than 15" above the cooktop and adjacent cabinetry 
is recommended to reduce exposure to steam, grease splatter and heat. Allow 1/4" minimum clearance 
at the back wall.
To reduce the risk of burns or fire when reaching over hot surface elements, cabinet storage space above
the cooktop should be avoided. If cabinet storage space is to be provided above the cooktop, the risk can 
be reduced by installing a range hood that projects at least 5" beyond the front of the cabinets. Cabinets
installed above the cooktop must be no deeper than 13".