Cma est-ah Owner's Manual

Page of 11
Operation 
 
3.3. 
Quick service guide 
MODEL EST INSTALLATION & OPERATION MANUAL Rev. 1.04 
Page
 
8
MODELS: VA AND EST 
 
 
 
 
 
TECHNICAL ISSUE 
Cause 
Solution 
Machine starts while doors are 
open 
Faulty magnetic door switch 
Replace the switch, P/N 00557.55 
  
Faulty start/fill switch  
Replace the switch, P/N 03470.01 
  
Faulty  #1 micro switch (start/stop) Replace micro switch, P/N 00411.00 
Continuous cycles 
Faulty start/fill switch  
Replace micro switch, P/N 00411.00 
  
Faulty door switch 
Replace the switch, P/N 00557.55 
  
Delimer switch in wrong position   Switch to 
NORMAL
 position 
Wash motor runs continuously 
Faulty delime switch 
Replace the switch, P/N 00475.00 
  
Faulty motor contactor  
Replace contactor, P/N 00404.82 
  
Delimer switch on wrong position   Switch to 
NORMAL
 position 
Sanitizer pump does not run 
Faulty delimer switch 
Replace the switch, P/N 00475.00 
  
Faulty # 6 micro switch  
Replace micro switch, P/N 411.00 
  
Faulty sanitizer pump motor 
Replace the motor, P/N 00416.00 
  
Broken Spring  
Replace spring, P/N 00105.82 
Drain valve does not operate 
Faulty #3 Micro switch  
Replace micro switch, P/N 00411.00 
  
Faulty drain motor 
Replace drain motor, P/N 00104.82 
  
Faulty #4 micro switch (Fill) 
Replace micro switch, P/N 00411.00 
  
Debris inside water solenoid valve  Clean valve replace diaphragm kit, 
P/N 00707.00 
Machine does not fill 
Faulty start/fill switch  
Replace the switch, P/N 03470.01 
  
Drain not closing 
check function of drain sys. 
  
Faulty water solenoid coil/valve 
Replace coil/valve, P/N 00738.10 or 
03603.10 
  
Faulty check valve 
Replace valve, P/N 00718.00 
Water leaks out of vacuum breaker  Low incoming water pressure 
Increase water pressure to 20 psi 
  
Faulty vacuum breaker kit 
Replace vac. Brkr kit, P/N 03623.00 
Machine only runs when start/fill 
switch is depressed 
Faulty #1 micro switch (start/stop)  Replace micro switch, P/N 00411.00 
  
Faulty magnetic door switch 
Replace door switch, P/N 00557.55 
Will not start/ nothing works 
Wall breaker tripped 
Reset breaker 
  
Master on/off switch faulty or in off 
position  
Reset or replace switch, P/N 00471.10
Runs, but none of the other 
functions engage  
Faulty #2 Micro switch (cycle 
reset) 
Replace micro switch, P/N 411.00 
  
Faulty ice cube relay (yellow relay) Replace relay, P/N 00636.00