Cma eva-ah-t Quick Setup Guide

Page of 2
Connect hard wire power supply from 
dishmachine to power box.
MODEL EVA REAR VIEW
DRAIN HOSE
HARD WIRE
 FOUR WIRE
POWER SUPPLY
1
2
3
4
Connect dishmachine to hot water source 
recommended 140
°  temperature (120° 
minimum temperature required).
Insert tube stiffener with chemical tubing
into each corresponding chemical 
dispensers. 
BLUE
RED
WHITE
4
STEP
TUBE
STIFFENER
TUBE
STIFFENER
AUTO START
SWITCH
2" DRAIN
OUTLET
POWER SWITCH
CHEMICAL
TUBING
CHEMICAL
TUBING
3/4" WATER 
INLET
3
HARD WIRE
POWER SUPPLY
2
HARD WIRE
POWER SUPPLY
NORMAL-OFF DELIMER
SWITCH
DRAIN/RINSE
SWITCH
SANI/DETERGENT
SWITCH
4
4
4
1/2" WATER 
INLET
1
2
3
4
Models EVA 
EVA-C, EVA-T
& EVA-C-T
Quick Setup 
Instructions
800-854-6417
WARNING
: Electrical and plumbing connections 
need to be made by a licensed service person 
and comply with all Federal, State and Local 
Health, Electrical, Plumbing and Safety codes.
WARNING
: Electrical and 
plumbing connections 
need to be made by a
licensed service person 
and comply with all
Federal, State and Local 
Health, Electrical,
Plumbing and Safety
codes.
5-2007
3
STEP
WALL 
DRAIN
8"
FLOOR DRAIN
Connect a 2" drain pipe (not
supplied) from scrap accumulator
to floor or wall drain. 
2
STEP
1
STEP
1
STEP
ON/OFF
POWER SWITCH