Soleus kfhhp-22 User Guide

Page of 26
 
- 11 -
 
 
 
               
Specifications and Technical Data 
 
Model 
KFHHP-22-ID / KFHHP-22-OD 
Function Heating 
and 
Cooling 
Cooling capacity(BTU/hr) & (Watts) 
22000 / 6450 (2250-7000) 
Heating capacity(BTU/hr) & (Watts) 
24200 / 7100 (1650-8500) 
Rated voltage 
208-230V~ 
Rated Frequency 
60Hz 
Cooling/Heating rated current(A) 
10.0/9.3 
Cooling/Heating rated power(W) 
3300/3200 
Cooling/Heating power input(W) 
2280/2250 
SEER 14 
EER/COP(W/W)  
HSPF 8.4 
Recycling Air Volume(m
3
/h) 
1100/1000/900 
Factory Charge 410A (lbs.)* 
R410A    5.3 lbs
 
Noise (Indoor/Outdoor) dBA 
50/59 
Maximum Vertical 
 
Height 
Differential 
Maximum Length 
 
Net Weight (Indoor/Outdoor) (lbs) 
38.6/138.9 
Dimensions (Indoor/Outdoor) 
(WxHxD)(inch) 
Indoor unit :46.38” ×12.83” × 8.98” 
Outdoor unit:37.40” × 33.07” × 16.54” 
 
 
1.  All above are tested and certified to ETL specification. 
2.  All above could be changed without notice; the latest specifications are on the nameplate of your air 
conditioner. 
When the unit is restarded after it stopping, it can automatically resume the last running mode, and the outdoor 
unit starts later. 
 
 
Working temperature range 
 
 Indoor 
side 
DB/WB(°F) 
Outdoor side DB/WB(°F) 
Maximum cooling 
90 / 74 
109 / 79 
Minimum cooling 
70 / 59 
70 / -- 
Maximum heating 
81 / -- 
75 / 64 
Minimum heating 
68 / -- 
23 / 21