Soleus sg-wac-06ese-c User Manual

Page of 16
SPECIFICATIONS 
•  Noise level is measured at a distance of 3.28 ft away from the front of the unit in cooling mode. 
•  Power consumption is measured when the fan runs at the highest speed setting. 
•  These specifications are for reference only. For actual data, please refer to the rating label on the
 unit. 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 5 
Model SG-WAC-06SE 
Power Supply (Ph/V/Hz) 
1/115/60Hz 
Dehumidifying Capacity (Pints/Day) 
31.2 
Rated Cooling Capacity (BTU/h) 
6,000 
Rated Heating Capacity (BTU/h) 
Cooling Power Input (Watts) 
620 
Heating Power Input (Watts) 
Rated Current Cooling (Amperage) 
5.6 
Rated Current Heating (Amperage) 
EER/C.O.P 9.7 
Noise Level db (A) H/L 
5
6/61 
CFM 1
80 
Design Pressure (PSIG) (H/L) 
Dimensions (W” x H” x D”) 
18.
59 x 12.75 x 15.72 
Package Dimensions (W” x H” x D”) 
21.8
4 x 14.19 x 17.91
Net/Gross Weight (Lbs) 
46/54 
Refrigerant Charge (Oz) 
12.35 
SG-WAC-08ESE 
1/115/60Hz 
40.8 
8,000 
740 
7.1 
10.8 
59/63 
2
00 
18.
59 x 12.75 x 15.72 
21.8
4 x 14.19 x 17.91
49/56 
16.58 
Refrigerant Type 
R-410A 
R-410A 
SG-WAC-06ESE 
1/115/60Hz 
36 
6,300 
590 
5.3 
10.7 
56/61 
180 
18.
59 x 12.75 x 15.72
21.8
4 x 14.19 x 17.91
46/54 
R-410A 
13.05