Soleus sg-wac-06ese-c User Manual

Page of 16
ASSEMBLY & INSTALLATION (CONT.) 
 
 
 
3/4” Screws 
 
 
 
 
Sash Lock 
 
 
6
 
 
 
 
 
 
MOUNTING HARDWARE 
Qty
Tools Needed:  
Phillips Screw Driver 
Drill (if plot holes are needed) 
Sash Lock and Foam Seal Installation 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
1.  Drive 3/4” screws into the top of the accordion panel 
frame and the top rail to securely attach the window air 
conditioner to the lower sash. (See FIG. 11/12)  
 
 
3. To secure the lower sash into place, use the sash lock 
and a 3/4” screw as shown below (See FIG. 12) 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
4.  For added insulation, cut the supplied insulation foam to 
the width of the window. Insert the foam between the 
window sashes to prevent air and objects from getting 
into the room. (See FIG. 13) 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
Removing the Air Conditioner from the      
Window  
1.  Turn the air conditioner off, and disconnect the power 
cord. 
2.  Remove the sash seal from between windows, and 
unscrew sash lock. 
3.  Remove the screws installed through the frame and 
frame lock. 
4.  Close (slide) the side panels into frame. 
5.  Keeping a firm grip on air conditioner, raise the sash 
and carefully “rock” air conditioner backward to drain 
any condensate water in base of unit. Be careful not to 
spill any remaining water while lifting unit from window. 
6.  Store parts WITH the air conditioner in the box 
FIG. 13
 
 
FIG. 13
 
 8