Soleus sg-wac-12hce User Manual

Page of 20
Recommended Ground Method 
For your personal safety, this air conditioner must be grounded. This air conditioner is equipped with a 3 prong power 
supply cord with a grounded plug. To minimize the possibility of electrical shock, the cord must be plugged into a 3 prong 
outlet and grounded in accordance with all local codes and ordinances. If a 3 prong outlet is not available, it is the cus-
tomer’s responsibility to have a properly grounded 3 prong outlet installed by a qualified electrician. 
LCDI Power Cord and Plug 
This air conditioner is equipped with an LCDI (Leakage Current Detection and Interruption) power cord that is required 
by UL. This power supply cord contains state-of-the-art electronics that sense leakage current. If the cord is damaged 
and leakage occurs, power will be disconnected from the unit. 
 
The test and reset buttons on the LCDI Plug are used to check if the plug is functioning properly. To test the plug:  
1.  Plug power cord into a grounded 3 prong outlet 
2.  Press RESET (on some units a green light will turn on). 
3.  Press the TEST Button, the circuit should trip and cut all power to the air conditioner (on some units a green light 
may turn off. 
4.  Press the RESET button for use. You will hear a click and the A/C is not ready for use. 
 
NOTES
•  The RESET (A) button must be engaged for proper use. 
•  The power supply cord must be replaced if it fails to trip when the TEST button (B) is pressed and the unit fails to 
reset. 
•  Do not use the power supply cord as an ON/OFF switch. The power supply cord is designed as a protection device. 
•  A damaged power supply cord must be replaced with a new power 
supply cord from Soleus Air Powered by Gree. 
•  The power supply cord contains new user serviceable parts. Open-
ing the tamper-resistant case voids all warranty and performance 
claims. 
 
NOTE: Your units power cord and plug may differ from the one shown. 
ELECTRICAL REQUIREMENTS 
 3 
Electrical Shock Hazard 
Plug into a grounded 3 prong outlet. 
Do not remove the ground prong. 
Do not use an adapter 
Do not use an extension cord. 
Failure to follow these instructions can result in death, 
fire, or electrical shock 
The electrical ratings for your air conditioner are listed on the model and serial 
number label located on the front left side of the unit (when facing the front). 
 
Specific electrical requirements are listed in the chart below. Follow the      
requirements below for the type of plug on the power supply cord. 
Power Supply Cord 
It is the customer’s responsibility: 
•  To contact a qualified electrician 
•  To assure that the electrical installation is adequate 
and in conformance with the National Electrical Code, 
ANSI/NFPA 70 - latest edition, and all local codes and 
ordinances. 
Copies of the standards listed may be obtained from:
 
National Fire Protection Association 
One Batterymarch Park 
Quincy, Massachusetts 02269 
NEMA 6-20P