APC MGE Galaxy 3500 20kVA 400V G35T20KH2B4S User Manual
![APC](https://files.manualsbrain.com/attachments/434134065d5c651f4d733496e262a45a75ce3ca6/common/fit/150/50/cb1a8b6f231ef4d783dd99279a1457344a0d4d6facb230ab9b5ba2f65edf/brand_logo.png)
Product codes
G35T20KH2B4S
MGE Galaxy 3500 - Features &
Benefits
Benefits
Rugged Industrial Environments
> Sturdy Enclosure
2mm heavy gate Steel front cover and frame
design.
> Easy replacable air filters
Prevent dust and debris from affecting UPS
performance (arrestance value of 80% as per
Ashrae 52.1)
> IP 51
Drip shield that prevents falling dirt and dripping
liquids from entering the UPS
> Floor anchoring
Prevent the UPS from tilting
> Wheels
Allow the UPS easily to be rolled into place
2mm heavy gate Steel front cover and frame
design.
> Easy replacable air filters
Prevent dust and debris from affecting UPS
performance (arrestance value of 80% as per
Ashrae 52.1)
> IP 51
Drip shield that prevents falling dirt and dripping
liquids from entering the UPS
> Floor anchoring
Prevent the UPS from tilting
> Wheels
Allow the UPS easily to be rolled into place
Options
> External Runtime Frame with Batteries
Adds additional runtime configuration with or
without Breaker
> Single Bypass Panel - wall-mounted
> Empty Frame for Third-party Batteries or
Transformers
Line up and match cabinets for third party
batteries and transformers
> Communication cards
Web/SNMP card supplied with the product,
Optional cards available for additional features
Adds additional runtime configuration with or
without Breaker
> Single Bypass Panel - wall-mounted
> Empty Frame for Third-party Batteries or
Transformers
Line up and match cabinets for third party
batteries and transformers
> Communication cards
Web/SNMP card supplied with the product,
Optional cards available for additional features
Reduced Total Cost of Ownership
> Up to 96% Efficiency
Minimizes energy loss and operating costs over
time
> Optimized footprint
Allows for a wide range of uses in Electrical rooms
and up to 60% space saving
> Reduced Electrical infrastructure rating
requirements
Reduced cost for wiring, transformers, generators
> Input power factor correction
Reduces installation costs
Minimizes energy loss and operating costs over
time
> Optimized footprint
Allows for a wide range of uses in Electrical rooms
and up to 60% space saving
> Reduced Electrical infrastructure rating
requirements
Reduced cost for wiring, transformers, generators
> Input power factor correction
Reduces installation costs
80
82
84
86
88
90
92
94
96
98
0
50
100
Load [%]
E
ffic
ie
n
c
y
[%
]
Low line voltage
Nominal line voltage
High line voltage
Battery operation
User-replaceable
air filters
IP51 enclosure
Maintenance
Bypass
Communication
Cards