Values are shown both in absolute (ABS) and ration (RATIO) format. The
PASS/FAIL test refers to the quality objectives set in G.826.
PASS/FAIL test refers to the quality objectives set in G.826.
5
Resets counters.
6.2.3. ADSL Alarm Status
The Alarms Status screen provides a current and history status of any alarm
conditions.
conditions.
Alarm information is provided simultaneously for the neared and far-end. The near-
end refers to the ATU-R side of the link, far-end to the ATU-C side of the link. The
screen also displays both current and history results. A CHANGE alarm means that
the alarm condition was detected in the past, but has been cleared.
end refers to the ATU-R side of the link, far-end to the ATU-C side of the link. The
screen also displays both current and history results. A CHANGE alarm means that
the alarm condition was detected in the past, but has been cleared.
Pressing
clears the flashing history LEDs. The alarm displayed has the
following meanings:
LOS: Loss of Signal
Near-End: occurs when the received pilot tone power is 6 dB or more below the
reference power (averaged over 100 ms). Far-End: indicates that a near-end loss of
signal was detected in
reference power (averaged over 100 ms). Far-End: indicates that a near-end loss of
signal was detected in