8.5  Miscellaneous Communication Features 
8.5.1 
Power-cycle Recovery 
There  are  times  when  the  host  needs  to  know  if  the  printer  was  power  cycled.  An  example  would  be 
changing the receipt tape. It is not necessary to turn the printer off to change the receipt. However, if the 
operator does, any information sent to the printer before the power cycle will be lost.  
 
The Series 90PLUS Printer has a flag that is set after a reset. The flag stays set until the host requests a 
reset. The [ENQ] <11> command reads the flag. If the command returns power-cycled status, the power has 
been reset or power cycled since the last request. All unprinted information has been lost. 
 
If  the  print  operation  is  critical,  it  is  a  good  idea  to  check  this  flag  before  and  after  all  transactions.  An 
alternate approach is to check the flag after every off-line to on-line transition. 
 
Note: If the printer mode was changed by the [ESC] y <2> or <3> command, a power-cycle reset will return 
to the power-on default. 
 
8.5.2 
Data Pass-through 
The  Series  90PLUS  Printer  supports  data  pass-through  (sometimes  referred  to  as  display  pass-through). 
This  mode  is  activated  by  the  print  suppress  command  with  the  pass-through  bit  set.  In  this  mode,  the 
printer  can  be  requested  to  transmit  any  data  that  it  receives  (pass-through).  Here,  the  printer’s  inquire 
commands are active but of little use. Typically, the printer’s transmit data is connected to the next device 
in line. Inquire commands have no data path back to the host. If pass-through is to be used, it is a good idea 
to deactivate the inquire commands. (Use [ESC] y <6> to do this). 
 
Before  pass-through  data  can  be  used,  it  must  be  activated  in  the  configuration  menu,  which  is  the  third 
selection in the print-suppress/pass option. 
 
All data after, but not including, the print suppress command is pass-through. When deactivated, the print 
suppress command is again not pass-through. During pass-through the multidrop commands are active (if 
configured). 
 
If a multidrop control command is found in the pass-through data, it will not be passed, and it will be acted 
upon. If the printer is deselected during pass-through, the printer will stop passing on the data. When the 
printer is readdressed, data pass-through will be active. 
 
8.5.3 
Multidrop Configuration 
The Series 90PLUS Printer supports a multidrop configuration where up to three printers can be connected 
in  parallel.  Each  printer  has  a  different  address,  “A,  B,  or  C.”  The  printer  will  not  accept  any  print 
information  unless  it  is  addressed.  Multidrop  configuration  is  only  available  in  serial  mode  as  parallel 
printers cannot be connected together.