Vinotemp 1500cd Leaflet

Page of 2
                                                                                
- 1 -
VINO1500CD, CTED 
VINO2500CD, CTED 
Installation Instruction 
 
1. Location 
 
•  Place the wine cellar in a properly ventilated location. Otherwise, heat 
exhausted by the cooling unit will build up and it will not operate properly.  
•  The exhaust area must not be closed space and must be ventilated. 
 
1) Rear Exhaust  
•  Leave min 6 “clearance from the rear to the wall. 
•  Leave min 12” clearance from the top to the ceiling. 
•  Leave min 6” clearance from the left and right sides. 
 
2) Front Exhaust  
•  Leave min 6” clearance from the front if left and right sides unobstructed. 
•  Or, leave min 36” clearance from the front if left and right sides obstructed 
 
3) Top Exhaust  
•  Leave min 12” from the top to the ceiling. 
•  Leave min 2 “clearance from the rear to the wall. 
•  Leave min 2” clearance from the left and right sides. 
 
4) Side Exhaust  
•  Leave min 6 “clearance from the left or right side to the wall. 
•  Leave min 12” clearance from the top to the ceiling.  
 
2. Installation 
 
Fig. 2.1 COOLING UNIT MOUNTING