Platform Menu 
LDS Plus Reference Guide 
E-SW-LDSPLUSRG-G 
Com2Power – COM2 Power Mode 
The Com2Power parameter controls whether the TE applies voltage to communications port 
number 2 (COM2). If the hardware does not have the ability to power a particular port, this setting 
is ignored. 
Note: 
This parameter setting has no effect on the current settings of COM2 baud rate, data 
bits, parity, stop bits, half duplex, software flow control (Xon), hardware flow control, 
time out, or pass termination character. 
Options 
Valid options:  
Off, On 
Default setting: 
On 
Access Level 
Parameter may only be modified by a user with an access level of 2 or 3. 
BarcodePrefix – Barcode Prefix in Hex 
Function 
The BarcodePrefix parameter enables the appending of a prefix character to a barcode scan. This 
character is denoted by its 2 digit hex value in the ASCII set. Addition of the prefix is done prior 
to the detection of barkeys. Excluded values must not be used. 
Example 
Set BarcodePrefix to 5c (the ASCII forward slash ‘\’) and BarcodeSuffix to 2f (the ASCII back 
slash ‘/’). A barcode symbol is scanned with the data “12345”. LDS Plus will attempt to enter the 
data “\12345/” into the Compose buffer. 
Options 
Valid options:  
00 
(Inhibits this parameter) 
 
 
 
20 - 7E, excluding: 
3c 
 
 
 
 
 
3e 
 
 
 
 
 
 
7b 
 
 
 
 
 
 
7d 
Default setting: 
00 
Access Level 
Parameter may only be modified by a user with an access level of 2 or 3. 
Refer to the tables in Appendix C, “Code Tables and Character Sets”, for code tables, decimal-
hexadecimal equivalencies and the DOS ASCII character set.