LXE 1280 Reference Guide
52
Emulation Menu Option
LDS Plus Reference Guide
E-SW-LDSPLUSRG-G
PowerUpMessage – Power Up Message
Function
The PowerUpMessage parameter determines whether the computer automatically transmits a
power up message to the host computer each time power is applied to the computer. This message
serves as a computer log on to the host.
power up message to the host computer each time power is applied to the computer. This message
serves as a computer log on to the host.
Options
Valid options:
Yes, No
Default setting:
No
Access Level
Parameter may only be modified by a user with an access level of 2 or 3.
CompressedXmit – Compressed Form Transmit Mode
Function
The CompressedXmit parameter determines whether the computer transmits form messages in a
shortened, compressed format or in the usual, uncompressed format.
shortened, compressed format or in the usual, uncompressed format.
Options
Valid options:
Yes, No
Default setting:
No
Access Level
Parameter may only be modified by a user with an access level of 2 or 3.
KeybdBufLen – Keyboard Buffer Length
Function
The KeybdBufLen parameter determines the maximum number of characters you can enter from
the keyboard into a non-form message.
the keyboard into a non-form message.
This parameter accepts values from 000 to 255. Leading zeros are not required.
Note:
An entry of 255 sets the keyboard buffer length to 520 characters. When the buffer length
is reached by keyboard entry, any additional characters entered simply replace the last
character entered.
is reached by keyboard entry, any additional characters entered simply replace the last
character entered.
Options
Valid options:
000 - 255
Default setting:
255
Access Level
Parameter may only be modified by a user with an access level of 2 or 3.