Maintenance Service and Trouble Shooting
 
④ The starter relay  or overload  protector is bad.  A  bad starter  normally is 
caused  by  a  burn  a  contact  points  or  the  welded  point  has  come  off;  a 
bad thermal protection unit is normally caused by burn contact points or 
a bad heating wire. 
⑤ The motor winding are burned. 
⑥ The compressor shaft is broken and blocking the cylinder. 
12.2.2 Operation of freezer is not normal   
Freezer  starts  when  power  is  switched  on,  but  after  a  few  seconds  or  1-2 
minutes,  it  stops  automatically  and  will  start  again  in  several  minutes.  It 
stops again within a very short time period after starting. If it runs like this 
 
Continuity  and  can  not  work  normally;  there  are  several  reasons  for  this 
matter: 
(1) Big fluctuation of voltage 
The voltage required for proper operation is 220V olts. If the voltage is too 
high,  the  current  flowing  through  the  starter  will  increase  accordingly. 
When it exceeds the permissible value, the starting contact point will keep 
in  connection  state  for  a  long  time  and  cannot  be  released  in  time  (at 
normal  situation,  the  motor  starting  coil  will  cut  off  in  about  1s  after 
starting).  This  will  make  the  coil  temperature  rising  rapidly,  and  then  the 
thermal protection unit cuts off the circuit and stop operation. When power 
is  cut  off,  the  temperature  of  thermal  protection  unit  reduces  quickly  and 
will  switch  power  on  when  reaching  the  reset  temperature.  At  this  time,  if 
the  contact  point  has  not  been  released,  the  starting  contact  point  could 
not  contact  tightly  and  it  is  in  false  connection.  This  will  make  the 
compressor tremble; thermal protection unit will open after a short time. 
(2) Operating amperage too high 
Freezer operation current is too big and will not operate normally. There are 
two reasons way: 