MAINTENANCE SERVICE AND TROUBLE SHOOTING
 
Maintenance Service and Trouble Shooting
 
12.7.2 Noise test 
At  the  geometrical  center  of  measuring  field,  put  the  freezing  freezer  onto 
an elastic base (5-6mm thick elastic rubber cushion). The freezer should be 
empty. Turn the knob of temperature controller to middle or near to strong 
position and close the door or cover. Make the measurement at least 30 min. 
after freezer operation.   
During test, if the freezer reaches the temperature the knob stipulated, and 
 
the freezer stops, the measurement must be interrupted and resume 3min. 
 
after the freezer starts again. 
The test environment is semi-sound-eliminating-room. Other test field must 
comply with the stipulations in GB4214. 
The  test  of  noise  is  carried  out  as  shown  in  figure  8.  Put  sound  transfer 
units to measurement point 1,2,3,4, measure the sound level by sound level 
meter  (A  weighted).  Take  the  greater  readings  and  calculate  the  average 
value.  The  arithmetic  average  value  of  these  four  points  is  taken  as  the 
average sound pressure level noise. 
According  to  the  testing  result,  sound  power  level  of  the  freezer  being 
measured can be calculated out. 
L
W
=(L
PA
-2)+10LgS 
Where: L
W
--A sound power level, dB (datum value is 1PW); 
              L
PA
 --average sound pressure level of measuring surface,           
                        dB(datum value is 20μPa); 
              S
—measuring surface enveloped area, m
2
 