Newco b145-0 Operating Guide

Page of 8
Man PN 151680 Iss 0
503 
 
PROGRAMING INSTRUCTIONS 
 
•  Depress and hold Cancel button until display lights up (Approx. 10 seconds). 
•  You are now in the Program Mode. Functions to be programmed appear in the order in which they are 
shown in the following table. 
•  Use the Cancel button to cycle through the functions to find the one you wish to change. 
•  Use the BREW 1 button to lower the displayed value and the BREW 2 button to raise the value. Press 
Cancel to store the changed value and advance to next function. 
•  If the Brewer detects no activity for approx. 60 seconds it will exit the Program Mode, except as noted 
below. 
 
CODE 
FUNCTION TO SET 
SET VALUES AVAILABLE 
LIGHTS ICON ADJACENT TO 
1A Brew 1 time 
    OFF, 30 seconds – 6 minutes BREW 1 
1b Brew 2 time 
      OFF, 30 seconds – 6 minutes BREW 2 
Visa-brew time 
OFF, 30  seconds – 2 ½ minutes 
BREW 1 and BREW 2 (both flashing) 
Water Temperature   1 
170 
°F – 205 °F  
SERVICE 
Auto Arm 
ON or OFF 
HEATING, (flashing) 
5A 
Pre-infusion 1 mode 
ON or OFF 
BREW 1, (pulsing), COFFEE MONITOR 
5b 
Pre-infusion 2 mode 
ON or OFF 
BREW 2, (pulsing), COFFEE MONITOR 
Pulse brew mode 
ON or OFF 
BREW 1 and BREW 2 (pulsing) 
6A 
Pulse brew 1 time    2 
0 seconds – 60 seconds 
BREW 1 (pulsing) 
6b 
Pulse brew 2 time    3 
0 seconds – 60 seconds 
BREW 2 (pulsing) 
7A 
Audible alert mode 
ON or OFF 
None 
7b 
Audible alert no. of beeps 
OFF, 1 - 9 
None 
Coffee freshness monitor 
(Not all models) 
10 minutes – 2 hours 
COFFEE MONITOR 
9A 
Filtering flow rate 
OFF, 0.25 – 1.00 gal. / min 
WATER FILTERING 
9b 
Filter capacity     4 
OFF, 0.50 – 2.50 gal. X 100 
WATER FILTERING, (flashing) 
10 
Number of Brews 
ON or OFF, Clr 
BREW 1 and BREW 2 
12A Power 
mode 
Normal, Power Save, Power Down 
None (Displayed  P: n, P: s and P: d respectively) 
12b 
Power shutdown time 5 
30 minutes – 4 hours 
None 
End 
None   6 
N/A “END” 
 
1.  Brewer will remain in this sequence indefinitely until CANCEL button is pressed.  Heating icon will 
track heater operation. 
2.  Hidden if pulse brew mode is OFF or brew 1 time is OFF. 
3.  Hidden if pulse brew mode is OFF or brew 2 time is OFF. 
4.  Hidden if filter flow rate is OFF. 
5.  Hidden when power save mode is normal. 
6.  Program mode will time out in 15 seconds at end of programming sequence.  
 
ERROR MESSAGES 
The following table explains the error messages which may be encountered on the brewer.  The error 
messages may be cleared by going into the program mode, using the brew buttons to display “Clr” and 
then pressing the cancel button. 
 
ERROR MESSAGE 
DESCRIPTION 
CAUSE 
Er1 
Fill run error 
The fill solenoid has either run for more than six minutes on the initial 
tank fill or 3 minutes in normal operation. 
Er2 
Heater run error 
The tank heater has run for more than 30 consecutive minutes. 
Er3 
Shorted probe 
Short in the thermistor circuit. 
Er4 
Open probe 
Break in the thermistor circuit. 
Ful 
Filter limit reached 
The selected filtering capacity of the filter has been reached