ELECTRICAL HOOKUP (CONT’D)
 
 
5)  Make electrical connections as shown below and on the wiring diagram on the back of manual. 
Tighten strain relief as applicable. 
 
6)  If the brewer has been converted from the original voltage as shown on the serial tag it will be necessary to apply the        
appropriate electrical rating decal (Pg 3, Items 5 and 8) in place on the serial tag to cover the previous rating. 
 
 
Item  Part No      Description 
 
  1 
701555  Cord, 15 A 
  2 
101035  Strain Relief, 15 A 
  3 
511005  Plate, Adapter 15 A 
  4 
701467  Cord/Plate Assy 15 A 
 
 
 
Includes 1,2 and 3 
  5 
701468  Label, Electrical Rating, 
  
 
120 
  6 
701466  Kit, GX Perm to Cord 
 
 
 
Includes 4 and 5 
 7  511054 Cable 
Connector 
  8 
701471  Label, Electrical Rating, 
  
 
120/240 
  9 
701469  Kit, GX Cord to Perm 
 
 
 
      Includes 7 and 8
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
INSTALLATION INSTRUCTIONS 
 
WARNING:
 - Read and follow installation instructions before plugging or wiring in machine to electrical circuit.  
 
REFER TO THE ILLUSTRATION ON PAGE 6 FOR LOCATION OF REFERENCED COMPONENTS 
 
1)  Place the decanter under brew basket, raise top evaporation cover and pour four decanters of water through the top 
pour-in screen. Water should come through the brew basket as the fourth decanter of water drains out of the pour in 
basin. If brewer does not have a pour in opening remove top cover and pour water directly into 
receiving pan. The 
brewer tank is now full and the unit may be plugged into or wired to an appropriate voltage circuit as indicated on the 
serial tag. 
 