Newco moo-cafe User Guide

Page of 36
 
25
Service – Calibration and Troubleshooting 
Hot & Cold (Ambient) Water Calibration
 
 
 
 
 
 
H2O Calibration Instructions
H2O Calibration applies to the following :
A. Hot Water flow rate
B. Cold Water (ambient) flow rate   
Calibration routine-Note: H2O Calibration is a factory 
setting & should not need re-calibration unless
A dispensing valve is replaced or the measured 
dispense volume does not match the displayed setting
Step 1
Press & hold Button 2 “Settings”
After approximately 5 seconds
Display will change to”- - -”
- - -
H2o
Step 2
Continue holding for approximately
8 more seconds until display 
Changes to “con”.  Do not release
button, after approx 8 more seconds
Display will change to “H2o”
 
NOTE: MACHINE MUST BE AT OPERATING TEMPERATURE PRIOR       
TO CALIBRATING HOT WATER FLOW RATE.