Newco ocs-16a Operating Guide

Page of 6
4
This feature uses the light on the left and right switches to alert the user that a brew cycle has either been initiated or is
in process and to use caution. This feature also has a calibration adjustment on the control board, which allows for the
calibration to continue the light flashing until the coffee completely drains from the brew basket.  Note:  A new brew cycle
will not be accepted until the switch light stops flashing. This design eliminates double brewing.
Power Modes:
Allows you to automatically save energy when the brewer is not in use for a specified length of time. By using the "Tank
Heater Mode" switch located on the back of the brewer you may select one of the three operation modes.
Mode I is the "Power Save" mode. In this mode the tank heater will be set back to 170
°
F after 2 hours of being
idle. The right switch light will flash once every minute to indicate that unit is in “Power Save” mode.
Mode II is the "Normal" mode. In this mode the tank temperature will be maintained at the temperature set on
the control board at all times.
Mode III is the "Power Down" mode. In this mode the tank heater element will be disabled after 2 hours of being
idle. The left switch light will flash once every minute to indicate unit is in power down mode.
By depressing the brew start switch the timer is reinitialized and the time frame starts over. In modes I and III the "Auto
Arm" feature will bring the tank up to temperature before brewing when the brew start switch is depressed.
Temperature Calibration & Tank System:
The system uses a solid state temperature control to maintain the water temperature in the tank with accuracy. Included
in the system is a water detection probe that prevents premature heater turn on when there is no water present in the
tank. Until water makes contact with the probe, the tank heater will not energize. Additionally, a back-up manual reset
limit control has been incorporated into the system, as well as heater run time protection. These features are designed to
protect the equipment in the event of an operator or component failure. For ease of service, access to the tank is
provided from the top of the unit.
ERROR CODES
Service Alert System:
The equipment is designed with maximum run time for the heating and water fill system. Listed below is a chart for
interpreting an error code when the brewer will not operate.
Error Code:
Problem Area:
Cause:
Check:
Heating Lamp flashes
continually
Water Fill
System detects that water valve has run
for 6 min. w/o making contact with probe.
Water supply to brewer, water filters &
water probe to see if limed up.
Left & Right switch lights
flash
Tank Heater
Tank heating system has run for 10-min.
w/o a 3-degree change in temperature.
Tank Heater, Main Thermostat &
Limit Thermostat
Right switch light flashes
Temperature Probe
Thermistor is open
Replace Thermistor
Left switch light flashes
Temperature Probe
Thermistor shorted
Replace Thermistor
IN CASES WHERE THERE IS A HEATER OR FILL PROBE ERROR, THE BREWER CAN BE RESET BY
HOLDING DOWN EITHER BREW START/STOP SWITCH FOR 10 SECONDS.  ERROR WILL CLEAR
WARRANTY
Newco coffee brewers are warranted against defects in workmanship or materials, under normal use, for 90 days from
the date of purchase. Brewer parts are warranted against defect for 12 months from date of purchase. Liability in all
events is limited to the purchase price paid and liability under the aforesaid warranty is limited to replacing or repairing
any part or parts which are defective in material or workmanship, and returned to our factory, shipping cost prepaid. No
warranty expressed or implied, other than the aforesaid is made or authorized by Newco Enterprises, Inc. Prompt
disposition will be made if item proves to be defective, within warranty. Before returning any item, write or call Newco, or
the dealer, from whom the product was purchased, giving model number, serial number, and date of purchase, and
describe the nature of the defect. If damage was incurred during transit to you, file claim with the carrier
CONTROL BOARD SETTING VALUES