Frigidaire fgqbb30ds0 Installation Instruction

Page of 20
5
CLOSET DOOR
60 sq. inches
(387.1 sq. cm)
15" (38.1 cm)
0" (0 cm)
60 sq. inches
(387.1 sq. cm)
1" (2.54 cm)
0" (0  cm)
0" (0 cm)
0" (0 cm)
0" (0  cm)
1" (2.54 cm)
LOCATION OF YOUR DRYER
DO NOT INSTALL YOUR DRYER:
1. In an area exposed to dripping water or outside weather
conditions.
2. In an area where it will come in contact with curtains, drapes,
or anything that will obstruct the flow of combustion and
ventilation air.
3. On carpet. Floor MUST be solid with a maximum slope of 1
inch (2.54 cm).
INSTALLATION IN RECESS OR CLOSET
1. A dryer installed in a bedroom, bathroom, recess or closet,
MUST be exhausted outdoors.
2. No other fuel burning appliance shall be installed in the same
closet as the Gas dryer.
3. Your dryer needs the space around it for proper ventilation.
DO NOT install your dryer in a closet with a solid door.
4. A minimum of 120 square inches (774.2 square cm) of opening,
equally divided at the top and bottom of the door, is required.
Air openings are required to be unobstructed when a door is
installed. A louvered door with equivalent air openings for the
full length of the door is acceptable. Closet door ventilation
required:  2 louvered openings each 60 square inches (387
square centimeters) — 3 inches (7.6 cm) from bottom and top
of door.
MINIMUM INSTALLATION CLEARANCES - Inches (cm)
SIDES     REAR
TOP
FRONT
Alcove
0 (0 cm)   0 (0 cm)
15 (38.1 cm)
Closet
0 (0 cm)   0 (0 cm)
15 (38.1 cm)
1 (2.54 cm)
NOTE:   Under counter and stack models - 0 inches (0 cm) for
sides,rear, and top.
5. The following illustrations show minimum clearance
dimensions for proper operation in a recess or closet
installation.