Electrical connection
 
The connection of the hobs to mains is effected via the flex and the three pin plug located underneath the 
hotplate. The appliance operate at a main voltage of 120V a.c., frequency 60Hz. Electric power absorption is 
about 1W for 5 gas burner version or 2W for 6 gas burners version. 
WARNING: Electrical Grounding Instructions: This appliance is equipped with a (three-prong) 
grounding plug for your protection against shock hazard and should be plugged directly into a 
properly grounded receptable. Do not cut or remove the grounding prong from this plug.   
 
Wiring diagrams
 
 
    Wiring 
diagram 
description 
 
For hotplate model A see Fig. 11.  
 
 
1. Cable terminal 
For hotplate model B see Fig. 12.  
 
 
2. Ignition switch 
3. Spark generator 
4. Ignition spark 
L. Black 
N. White 
T. Green (earth) 
 
Room ventilation – Location and venting. 
ATTENTION: An exhaust fan may be used with the appliance; in each case it shall be installed in 
conformity with the national standards in force. 
ATTENTION: Exhaust hood operation may affect other vented appliances; in each case it shall be 
installed in conformity with the national standards in force. 
Conversion to different types of gas 
Before carrying out any maintenance work, disconnect the appliance from the gas and electric 
supply. For Natural Gas fit regulator assembly described in Fig. 5. For LP Gas fit assembly described 
in fig. 5. 
 
 - CHANGING THE NOZZLES FOR USE WITH OTHER TYPES OF GAS: 
To change the nozzles of the burners  use the following procedure:  
Lift up the burners and unscrew the nozzles ( Fig. 7) using an adjustable spanner of 7 mm and change the 
nozzles with those designed for the new gas supply according to the information given in TABLE A shown 
below. 
 
TABLE A: Adapting to different types of gas     
Drop-in cooktop with 5 workyop burners model B3W0..U4X(2 or 5)D 
Burner
 
Position Inj. 
size
 
Gas 
Pressure 
Max Rate 
Min Rate 
By-pass size
  
1/100mm 
Type 
[i.w.c.] 
[BTU/h] 
[W] 
[BTU/h] 
[W] 
[1/100mm] 
Auxiliary
 
Front R 
0,90 
NG 
4” 
3400 
996 
900 
264 
Regulated 
  
0,54 
LP(Propane)
11” 
3400 
996 
900 
264 
0,29 
Semi-Rapid
 
Rear L 
1,18 
NG 
4” 
6100 
1787 
1500 
439 
Regulated 
 Rear 
0,70 
LP(Propane)
11” 
6100 
1787 
1500 
439 
0,37 
Rapid
 
Front L 
1,55 
NG 
4” 
10400 
3047 
3700 
1084 
Regulated 
  
0,92 
LP(Propane)
11” 
10400 
3047 
3700 
1084 
0,58 
 Centre 
Inner 
0,80 
NG 
4” 
2800 
820 
900 
264 
Regulated 
Dual  
0,49 
LP(Propane)
11” 
2800 
820 
900 
264 
0,29 
burner 
Centre Outer 
N°2 x 1,15 
NG 
4” 
12000 
3516 
5300 
1553 
Regulated 
 
 
N°2 x 0,70 
LP(Propane)
11” 
12000 
3516 
5300 
1553 
0,73 
 
Drop-in cooktop with 6 workyop burners model B3Y0..U4X(2 or 5)D 
Burner
 
Position Inj. 
size
 
Gas 
Pressure 
Max Rate 
Min Rate 
By-pass size
  
1/100mm 
Type 
[i.w.c.] 
[BTU/h] 
[W] 
[BTU/h] 
[W] 
[1/100mm] 
Auxiliary
 
Front R 
0,90 
NG 
4” 
3400 
996 
900 
264 
Regulated 
  
0,54 
LP(Propane)
11” 
3400 
996 
900 
264 
0,29 
Semi-Rapid
 
Rear L & C 
1,18 
NG 
4” 
6100 
1787 
1500 
439 
Regulated 
 Front 
0,70 
LP(Propane)
11” 
6100 
1787 
1500 
439 
0,37 
Rapid
 
Front L 
1,55 
NG 
4” 
10400 
3047 
3700 
1084 
Regulated 
  
0,92 
LP(Propane)
11” 
10400 
3047 
3700 
1084 
0,58 
 Centre 
Inner 
0,80 
NG 
4” 
2800 
820 
900 
264 
Regulated 
Dual  
0,49 
LP(Propane)
11” 
2800 
820 
900 
264 
0,29 
burner 
Centre Outer 
N°2 x 1,15 
NG 
4” 
12000 
3516 
5300 
1553 
Regulated 
 
 
N°2 x 0,70 
LP(Propane)
11” 
12000 
3516 
5300 
1553 
0,73 
CAUTION: save the orifices removed from the appliance for future use