Section 7: Interface Specifications
CG4 Series Operator Manual
Page 7-15
7.5 LOCAL AREA NETWORK (LAN) ETHERNET (cont’d)
Notes
1) For the detailed On-board LAN interface settings, refer to the included [Setup Guide] and the Network 
Utility of [SATO Accessory CD-ROM].
2) To open/close Print data port (Port1024), Status port (Port1025) or Sending/Receiving port (Port9100), 
make sure to close and open the port at intervals of approximately 150ms to 200ms. If you don't have 
enough time from closing to opening the port, it may result in double connection. 
If the host requests the connection to the port already connected (Port1024, Port1025 or Port9100), the 
printer accepts the request (establishing double connection); however, the printer disconnects the second 
connection immediately.
3) Do not connect and disconnect the LAN cable while starting up the printer. Restart the printer with which 
you are having a communication error due to connection/disconnection of the LAN cable.