IBM 600 User Manual

Page of 124
Symptom-to-FRU Index
Symptom / Error
FRU / Action in Sequence
1XX
  1. System board
2XX
 
201: Memory data
error.
202: Memory line error
00–15.
203: Memory line error
16–23.
 
205: Memory test
failure on on-board
memory.
221: ROM to RAM
remap error.
1. Go to “Memory
Checkout” on
page  33.
  2. DIMM card
  3. System board
225
(Unsupported memory
module.)
1. Check if the
supported DIMM is
installed
.
  2. DIMM card
  3. System board
301, 303, 304, 305, 3XX
(301:  Keyboard error.)
1. Go to “Keyboard or
Auxiliary Input
Device Checkout” on
page  32.
  2. Keyboard
  3. External numeric
keypad
  4. External keyboard
  5. Keyboard/mouse cable
  6. System board
601, 6XX
(601: Diskette drive or
controller error.)
1. Go to “Diskette Drive
Checkout” on
page  31.
  2. Diskette drive
assembly
  3. Diskette
  4. System board
602
(Diskette read error.)
1. Go to “Diskette Drive
Checkout” on
page  31.
  2. Diskette
  3. Diskette drive
assembly
604
(Unacceptable ID was read
from the diskette drive.)
1. Go to “Diskette Drive
Checkout” on
page  31.
  2. Diskette drive
assembly
  3. System board
2402
1. TV Out Card
24XX
(2401: System board video
error.)
  1. System board
   
ThinkPad 600