IBM 600 User Manual
Symptom-to-FRU Index
Symptom / Error
FRU / Action in Sequence
1XX
1. System board
2XX
201: Memory data
error.
202: Memory line error
00–15.
203: Memory line error
16–23.
error.
202: Memory line error
00–15.
203: Memory line error
16–23.
205: Memory test
failure on on-board
memory.
221: ROM to RAM
remap error.
failure on on-board
memory.
221: ROM to RAM
remap error.
1. Go to “Memory
Checkout” on
page 33.
page 33.
2. DIMM card
3. System board
3. System board
225
(Unsupported memory
module.)
(Unsupported memory
module.)
1. Check if the
supported DIMM is
installed.
installed.
2. DIMM card
3. System board
3. System board
301, 303, 304, 305, 3XX
(301: Keyboard error.)
(301: Keyboard error.)
1. Go to “Keyboard or
Auxiliary Input
Device Checkout” on
page 32.
Device Checkout” on
page 32.
2. Keyboard
3. External numeric
3. External numeric
keypad
4. External keyboard
5. Keyboard/mouse cable
6. System board
5. Keyboard/mouse cable
6. System board
601, 6XX
(601: Diskette drive or
controller error.)
(601: Diskette drive or
controller error.)
1. Go to “Diskette Drive
Checkout” on
page 31.
page 31.
2. Diskette drive
assembly
3. Diskette
4. System board
4. System board
602
(Diskette read error.)
(Diskette read error.)
1. Go to “Diskette Drive
Checkout” on
page 31.
page 31.
2. Diskette
3. Diskette drive
3. Diskette drive
assembly
604
(Unacceptable ID was read
from the diskette drive.)
(Unacceptable ID was read
from the diskette drive.)
1. Go to “Diskette Drive
Checkout” on
page 31.
page 31.
2. Diskette drive
assembly
3. System board
2402
1. TV Out Card
24XX
(2401: System board video
error.)
(2401: System board video
error.)
1. System board
ThinkPad 600