IBM 600 User Manual
Symptom-to-FRU Index
PC Card-Related Symptoms
Symptom / Error
FRU / Action in Sequence
PC Card does not work in
either the upper slot or the
lower slot.
either the upper slot or the
lower slot.
Diagnostic error code:
DEV 080
ERR 33
FRU 7210
ERR 33
FRU 7210
1. Reseat the PCMCIA
slot assembly.
2. PCMCIA slot assembly
3. System board
PCMCIA slot pin is
damaged.
damaged.
PCMCIA slot assembly
PC Card does not work.
1. Reseat the PC Card
2. Check that the PC
2. Check that the PC
Card is enabled in the
ThinkPad Configuration
program
ThinkPad Configuration
program
3. Reseat the PCMCIA
slot assembly.
4. PCMCIA slot assembly
5. System board
Peripheral-Device-Related Symptoms
Symptom / Error
FRU / Action in Sequence
The external monitor does
not work correctly.
not work correctly.
Connect the external
monitor to another PC. If
the monitor works fine,
replace the system board.
If not, replace the external
monitor.
monitor to another PC. If
the monitor works fine,
replace the system board.
If not, replace the external
monitor.
Printer problems.
1. Run printer self-test.
2. Run parallel port wrap
2. Run parallel port wrap
test.
3. System board
4. Printer cable
4. Printer cable
Serial or parallel port device
problems.
problems.
1. Run serial/parallel
port wrap test.
2. Device
3. System board
4. Device cable
3. System board
4. Device cable
ThinkPad 600
63