Symptom-to-FRU Index
PC Card-Related Symptoms
Symptom / Error
FRU / Action in Sequence
PC Card does not work in
either the upper slot or the
lower slot.
Diagnostic error code:
DEV  080
ERR  33
FRU 7210
1. Reseat the PCMCIA
slot assembly.
2. PCMCIA slot assembly
  3. System board
PCMCIA slot pin is
damaged.
PCMCIA slot assembly
PC Card does not work.
1. Reseat the PC Card
2. Check that the PC
Card is enabled in the
ThinkPad Configuration
program
3. Reseat the PCMCIA
slot assembly.
4. PCMCIA slot assembly
  5. System board
 Peripheral-Device-Related Symptoms
Symptom / Error
FRU / Action in Sequence
The external monitor does
not work correctly.
Connect the external
monitor to another PC. If
the monitor works fine,
replace the system board.
If not, replace the external
monitor
.
Printer problems.
1. Run printer self-test.
2. Run parallel port wrap
test.
  3. System board
  4. Printer cable
Serial or parallel port device
problems.
  1. Run serial/parallel
port wrap test.
  2. Device
  3. System board
  4. Device cable
   
ThinkPad 600