IBM 560x Hardware Manual

Page of 110
      
 
 Checkout Guide
Use the following procedure as a guide for computer
problems. The diagnostic tests are intended to test only
IBM products.
1. Obtain the failing symptoms in as much detail as
possible.
2. Verify the symptoms by attempting to re-create the
failure by running the diagnostic test or by repeating
the same operation. (To run the diagnostics, refer to
“Running the Diagnostics” on page 47.
3. Use the following table with the verified symptom to
determine which page to go to. Search the
symptoms column, and find the description that best
matches your symptom; then go to the page shown in
the “Go To” column.
Symptoms (Verified)
Go To
Power failure. (The
power indicator does not
go on or stay on.)
“Power Systems
Checkout” on page 30.
POST does not
complete. No beep or
error codes are
indicated.
“Symptom-to-FRU
Index” on page 36, and
then use the No Beep
Symptoms
 table.
POST beeps, but no
error codes are
displayed.
“Symptom-to-FRU
Index” on page 36, and
then use the Beep
Symptoms
 table.
POST detected an error
and displayed numeric
error codes.
“Symptom-to-FRU
Index” on page 36, and
then use the Numeric
Error Codes
 table.
The diagnostic test
detected an error and
displayed a FRU code.
“Running the
Diagnostics” on
page  47.
The configuration is not
the same as the
installed devices.
“Checking the Installed
Devices List” on
page  49.
Other symptoms (such
as LCD display
problems).
“Symptom-to-FRU
Index” on page 36, and
then use the Other
Symptoms
 table.
Symptoms cannot be
re-created. (Intermittent
problems.)
Use the customer
reported symptoms and
go to “Symptom-to-FRU
Index” on page 36.
26