IBM 560x Hardware Manual

Page of 110
      
 
4. If the voltage is more than 
+
11.0 V dc, measure the
resistance between battery terminals 3 and 4. The
resistance must be 4 to 30 K ohm.
If the resistance is not correct, replace the battery
pack. If the resistance is correct, replace the DC/DC
card. If the problem persists, replace the system
board.
Checking the Backup Battery
1. Power off the computer and unplug the AC Adapter
from the computer.
2. Turn the computer upside down.
3. Remove the DIMM cover and backup battery (see
“1010 Backup Battery” on page 60).
4. Measure the voltage of the backup battery. See the
following figure.
Ÿ
If the voltage is correct, replace the system board.
Ÿ
If the voltage is not correct, replace the backup
battery.
Ÿ
If the backup battery discharges quickly after
replacement, replace the system board.
Wire
Voltage (V dc)
Red
+
2.5 to 
+
3.7
Black
Ground
Status Indicator Checkout
If an LED problem occurs, do the following:
1. Power off the computer.
2. Power on the computer.
3. All the LEDs in the indicator panel should turn on for
a moment after the computer is powered on. Make
sure they turn on.
If the problems persists, replace the system board.
System Board Checkout
The processing functions are performed by the system
board. When a numeric code calls the system board as a
FRU, use the following procedure to isolate the problem:
32
IBM ThinkPad 560X (2640-60x, 70x) HMM