IBM 770 Hardware Manual

Page of 136
     
 
SYMPTOM-TO-FRU INDEX
 
Symptom / Error
FRU / Action in Sequence
2XX
 
201: Memory data
error.
202: Memory line error
00–15.
203: Memory line error
16–23.
 
205: Memory test
failure on on-board
memory.
221: ROM to RAM
remap error.
1. Go to “Memory
Checkout” on
page  33.
  2. DIMM card
  3. System board
301, 303, 304, 305, 3XX
(301:  Keyboard error.)
1. Go to “Keyboard or
Auxiliary Input
Device Checkout” on
page  32.
  2. Keyboard
  3. External numeric
keypad
  4. External keyboard
  5. Keyboard/mouse cable
  6. System board
  7. DC-DC Card
601, 6XX
(601: Diskette drive or
controller error.)
1. Go to “Diskette Drive
Checkout” on
page  31.
  2. Diskette drive
assembly
  3. Diskette
  4. System board
602
(Diskette read error.)
1. Go to “Diskette Drive
Checkout” on
page  31.
  2. Diskette
  3. Diskette drive
assembly
604
(Unacceptable ID was read
from the diskette drive.)
1. Go to “Diskette Drive
Checkout” on
page  31.
  2. Diskette drive
assembly
  3. System board
808X
 
8081: PCMCIA
presence test failure.
(PCMCIA revision
number also checked.)
 
8082: PCMCIA register
test failure.
1. Reseat the PC Card
slot assembly.
  2. PCMCIA device
  3. System board
   
ThinkPad 770, 770E, 770X and 770Z
55