Phonic max 1000 User Guide

Page of 16
10
MAX 1000 / 1600
PROTECTION
The  unit  comes  with  many  circuitry  protection  features 
that protecting it and the speakers it’s connected to from 
harm.
SHORT CIRCUIT:  When speakers short circuit, this fea-
ture protects the amplifier by cutting off the output current 
to the speakers.
THERMAL:  Heat is created during high level output – es-
pecially when operating under bridge mono mode.  The 
unit comes with a variable speed fan that auto-adjusts the 
fan speed depending on the temperature of the machine.  
However, if for some reason the unit can not effectively vent 
out excessive heat, this feature will protect the unit from 
over-heating by shutting the unit down.
OUTPUT DC OFFSET:  When a direct current enters the 
connection between the power amplifier and speakers, it 
will negatively affect the speakers by causing the drivers 
and cones to work under stressful conditions. This feature 
ensures this does not happen by cutting off the output cur-
rent to the speakers when such a situation occurs.
POWER  ON  /  OFF  MUTING:   There  is  a  two  to  three 
second delay before the unit sends out any signal.  During 
this short delay, the entire system will be muted ensuring 
no signal affects your signal.  
SUBSONIC:  Frequencies below 10Hz contain high level 
of energy that can be harmful and stressful to many speak-
ers.  Since the normal human listening range is between 
20 Hz and 20 kHz, this unit comes with a feature that helps 
filter out any frequency that is below 10 Hz to protect your 
speakers.
RF PROTECTION:  Radio waves are everywhere. This fea-
ture prevents radio frequency interference from affect your 
signal by filtering out signals above 200 kHz. This ensures 
that radio program signals do not entering the unit.
AC POWER CONSIDERATIONS
The voltage level of the MAX amplifier will depend on your 
region.  Ensure that the local voltage levels are identical 
by those required by your amplifier before attempting to 
connect it to an AC outlet.  This is particularly important if 
you intend to take the amplifier overseas.  
Users are advised that they do not remove the ground pin 
on the MAX amplifier’s AC connector under any circum-
stances.
As the amount of power that the MAX amplifier consumes 
can differ greatly depending on the program material being 
amplified, it’s important that a stiff supply of AC power is 
available for the unit.  The more power available to the unit, 
the better the output will sound; particularly in low frequency 
peaks.  If you have more than one amplifier sharing a single 
AC  outlet,  turning  them  on  at  the  same  time  should  be 
avoided at all costs.  Turning them on in sequential order 
will help prevent tripping any circuit breakers.
INPUT WIRING
For  balanced  signals,  users  should  use  3-conductor 
shielded  cable  with  XLR  connectors  on  either  end.  For 
unbalanced signals, 2-conductor shielded cable with XLR 
connectors on either end can be used instead.  Balanced 
cables  should  be  wired  according  to Audio  Engineering 
Society standards.  
XLR?  The name of this kind of connector is derived from 
an X connector from Cannon.  These are the large, round 
connectors that contain three small pins that are arranged 
in a triangular shape.
Hot (+) – Pin 2
Cold (–) – Pin 3 
Shield (Gnd) – Pin 1