Q: What is the default IP address of the TPE-S88?
A:
  The default IP address is http://192.168.0.1
TPE-S88 F.A.Q.
Q: What is the default password?
A:
 
Q: How do I configure the switch through the web-based configuration?
A:
 
Q: How do I reset my switch to factory defaults?  
A:
 
Q: Why are my ping requests slower when using TRENDnet Web SMART 
Switches?
A:
 
Q: Why doesn’t my Cisco 7940G/7960G IP Phone power on when connected to my 
TPE-S88?
A:
 
The default password is admin.
Log into the switch by entering the default IP address into the browser.  The default IP address is 
http://192.168.0.1 and the password is admin.
Locate the reset button on the back of the switch.  Press and hold it in for approximately 15 
seconds. 
Since Web Smart switches are not as robust in features as fully managed switches they have a 
slower CPU. Therefore, depending on what processes the Web Smart switch is currently running, 
the ping response time will be varied and longer.
The Cisco 7940G and 7960G are pre-802.3af POE devices. They will not be able to get power 
from the POE switch. 
The following link is provided for reference and may provide further information regarding the 
incompatibility between 802.3af compliant devices and Cisco phones. 
This article is not provided by Cisco nor endorsed by TRENDnet: http://www.voip-info.org/wiki-
Cisco+POE 
Note: This may include other Cisco IP Phones that are not 802.3af compliant. For further 