3com 8807 Reference Guide

Page of 1099
886
C
HAPTER
 50: P
O
E C
ONFIGURATION
 C
OMMANDS
poe power-management
Syntax
poe power-management { auto | manual } slot slot-num
View
System view
Parameter
slot-num: Number of the slot where the module resides.
auto: The switch automatically manages the PoE mode on a module.
manual: You need to manually manage the PoE mode on a module on the switch.
Description
Use the poe power-management command to configure the PoE power 
management mode for a module on the switch.
By default, you need to manually manage PoE on the module on the switch.
Before the power supply is almost fully loaded, the system powers all ports. 
Working together with the command for configuring PoE priority on a port, this 
command takes effect when the external power supply by the switch is almost 
fully loaded.
The following section describes PoE in auto mode and in manual mode:
Auto mode: Priority management mode. If new PDs are connected to the 
switch when the external power supply is almost fully loaded, the switch first 
powers the PD connected to the port whose PoE priority is the highest. For 
example, assume that the PoE priority on port A is set to critical. If a new PD is 
connected to port A when the external power supply by the switch is almost 
fully loaded, the switch stops powering the PD connected to the port whose 
PoE priority is the lowest and begins to power the PD connected to port A.
Manual mode: If new PDs are connected to the switch when the external 
power supply is almost fully loaded, the switch disregards the PoE priority of 
the port but notifies you that a new device is connected, without changing the 
original PoE status. For example, assume that the PoE priority on port A is set to 
critical. If a new PD is connected to port A when the external power supply by 
the switch is fully loaded, the switch notifies you that a new device is 
connected but will not power the device connected to port A.
Related command: poe priority.
Example
# Configure the switch to automatically power the PD connected to the module in 
slot 2.
[SW8800]poe power-management auto slot 2 
# Restore the mode in which the switch powers the PD connected to the module 
in slot 2 to manual.
[SW8800] poe power-management manual slot 2