3com 8807 Reference Guide

Page of 1099
51
P
O
E PSU S
UPERVISION
 C
OMMANDS
PoE PSU Supervision 
Display Commands
display poe-power 
ac-input state
Syntax
display poe-power ac-input state
View
Any view
Parameter
None
Description
Use the display poe-power ac-input state command to display the AC input 
state of each power supply unit (PSU).
Example
# Display the AC input state of each PSU.
<SW8800> display poe-power ac-input state
 
PSU 1 AC Input State : Lack Phase
 
PSU 2 AC Input State : Normal
 
PSU 3 AC Input State : Lack Phase 
display poe-power 
alarm
Syntax
display poe-power alarm
View
Any view
Table 120   Description on the fields of the display poe-power ac-input state command
Field 
Description 
NORMAL 
The AC input is normal. 
Under Limit  The AC input is below the lower threshold. 
Upper Limit  The AC input is above the upper threshold. 
Lack Phase 
The AC input is lack of phase. 
Fuse Broken  The fuse is blown. 
Switch Off 
The switch is off.