GE pt916 Specification Guide

Page of 3
Listed by 
Underwriters 
Laboratories
For answers to your Monogram,
® 
GE Profile
 or  
GE
®
 appliance questions, visit our website at 
ge.com or call GE Answer Center
®
 service, 
800.626.2000.
Specification Revised 6/09
220241
PT916BM/CM/WM 
GE Profile
 30" Built-In Single Convection Wall Oven
 
KW Rating
240V
4.5
208V 3.4
Breaker Size
240V
20 Amps
208V 20 Amps
Dimensions and Installation Information (in inches)
Most 30” Wall Cabinets can be used with this unit.
Note:
 These ovens are not approved for 
stackable installations. Cabinets installed 
adjacent to wall ovens must have an adhesion 
spec of at least a 194°F temperature rating.
Door handle protrudes 3" from door face. Cabinets 
and drawers on adjacent 45° and 90° walls should 
be placed to avoid interference with the handle.
Electric wall ovens are not approved for 
installation with a plug and receptacle. They 
must be hard wired in accordance with  
installation instructions
Installation Information: Before installing, consult 
installation instructions packed with product for 
 current dimensional data.
Side-by-side installations rerquire at least 2" 
between cutouts.
CL
2 x 4 or
equivalent
runners
Suitable
bracing
to support
runners
21-5/8"
over centerline
of cabinet
(must support 275 lbs.)
Cutout width
28-1/2'' MIN.
28-5/8'' MAX.
29-3/4
C
30
Recommended 
cutout location 
32-1/2" 
from floor
21
Junction 
box
location
Allow minimum of 21'' for clearance
to adjacent corners, drawers, walls, or etc.
A=Allow 1" overlap of oven over top and bottom edges of cutout.
B=Allow 11/16"–3/4" for overlap of oven over side edges of cutout.
C=28-1/4" without trim and 28-3/4" with trim.
Conduit 
48-1/2" 
5
27-1/4'' MIN.
27-5/16'' MAX.
Cutout height
A
B
23-1/2'' MIN.
Cutout depth
22'' MIN.
CL
2 x 4 or
equivalent
runners
Suitable
bracing
to support
runners
21-5/8"
over centerline
of cabinet
(must support 275 lbs.)
Cutout width
28-1/2'' MIN.
28-5/8'' MAX.
29-3/4
C
30
Recommended 
cutout location 
32-1/2" 
from floor
21
Junction 
box
location
Allow minimum of 21'' for clearance
to adjacent corners, drawers, walls, or etc.
A=Allow 1" overlap of oven over top and bottom edges of cutout.
B=Allow 11/16"–3/4" for overlap of oven over side edges of cutout.
C=28-1/4" without trim and 28-3/4" with trim.
Conduit
(72" 
long)
5
27-1/4'' MIN.
27-5/16'' MAX.
Cutout height
A
B
23-1/2'' MIN.
Cutout depth
22'' MIN.