Bunn cdbcf 15 User Guide

Page of 48
Page 10
AXIOM
VERSION    ##.##
REVERSE
FORWARD
TECHNICIAN PROGRAMMING REMINDERS
ACCESSING PROGRAM MODES 
Press and hold the right hidden switch. The longer you press it, the higher the level you can access. EXAMPLE: 
Pressing for a couple seconds enters Level 1. Continuing to press for approximately 5 seconds will access Level 
2. Continue pressing for approximately 15 seconds to access Level 3. During program modes, use the right hid-
den switch to advance forward through screens. Use left hidden switch to step backwards through screens.
VIEWING ASSET AND SERIAL NUMBERS
Press left hidden switch to view Asset number. Press and release to view serial number. Press and release again 
to view the installed software version.
FACTORY BLOWOUT MODE
When in the main screen, DO NOT press both left and right hidden switches at the same time. The display will 
read "FACTORY BLOWOUT" "ON/OFF". WARNING: NEVER activate this mode. It will open the brew and refi ll 
valves simultaneously. THIS IS FOR FACTORY USE ONLY! If you accidentally enter this screen, exit out of it 
by pressing the 
"ENABLE BREW ON/OFF" switch.
REVERSE
FORWARD
VIEW ASSET/SERIAL #
ENTER PROGRAMMING
PROGRAMMING LOCKOUT SWITCH 
(Mounted on main control board)
This switch can be set to prevent access 
to Level 2. Turn "OFF" the switch to access 
Technician (Level 2). Once all the correct brew 
settings are programmed, the Technician can 
set the switch to the "ON" position to prohibit 
anyone from changing the settings. With the 
switch in the "ON" position, only Level 1 can 
be accessed by store personnel. Technicians 
can access Level 1 with the switch in either 
position. To enter Levels 2, 3, & 4, press and 
hold right hidden switch.
39132 062309