Bunn cdbcf 15 User Guide

Page of 48
Page 24
Location:
 
The  warmer element(s) is located under the warmer 
plate.
Test Procedures:
1.  Disconnect the brewer from the power source.
2.  With a voltmeter, check voltage across the two 
wires at the warmer element with the "ON/OFF" 
switch in the "ON" position. Connect the brewer 
to the power source. The indication must be 120 
volts ac for two wire 120 volt models and three 
wire 120/208 and 120/240 volt models, or 230 
volts ac for two wire 230 volt models.
3.  Disconnect the brewer from the power source.
If voltage is present as described, proceed to #4.
If voltage is not present as described, refer to Wiring 
Diagrams and check wiring harness.
4.  Check the resistance across the two terminals on 
the warmer element. Refer to chart below.
If resistance is to specifi cation, reconnect the two 
wires to the warmer element.
If resistance is not to specifi cation, replace the 
warmer element.
Removal and Replacement:
1.  Remove the three #4-40 screws securing the 
warmer assembly to the brewer.
2.  Lift the warmer assembly from the brewer.
3.    Disconnect the two wires from the warmer element 
terminals.
4.  Remove the two #8-32 nuts securing the warmer 
element to the warmer plate.
5.  Securely install new warmer element.
6.  Reconnect the two wires to warmer element ter-
minals.
7.  Securely install warmer assembly on the brewer.
 
FIG. 24-1  WARMER ELEMENTS
WARMER ELEMENTS
  100W-120V   
 
144.0 
  100W-220V   
 
484.0 
  100W-200V   
 
400.0 
      WARMER                   RESISTANCE
TERMINAL TO SHEATH - INFINITE (OPEN)
FIG. 24-2  WARMER ELEMENTS
39132 041708