Bunn dual sh brewwise dbc Operating Guide

Page of 54
Page 38
SERVICE TOOLS (cont.)
is functional, the sound of the valve operating will 
be heard.
21. Press OFF to end testing of refill valve.
22. Press NEXT to advance to the next component to 
be tested.
23. To test TANK HEATERS, connect a voltmeter across 
each of the tank heaters to check for voltage.
24. Press ON. The correct voltage should be present 
at the heater terminals.
25. Press OFF to end testing of the tank heaters.
NOTE: The tank heater will automatically turn off if 
left on too long.
26. After testing the tank heater, press NEXT to advance 
to the next test.
27. The HEATER CONTACTOR is used only on certain 
models. Check the machine schematic to see if the 
contactor is present. Connect a voltmeter across a 
tank heater that is operated by the contactor and 
press ON to check that correct voltage is present. 
Press OFF and confirm the voltage is zero.
28. Press NEXT to return to TEST OUTPUTS.
29. To exit SERVICE TOOLS, press and release either 
ON/OFF switches located on the front switch panel. 
This will return to the MAIN SCREEN.
Procedure to test switches:
 
This function allows the operator to test the opera-
tion of the individual switches on the front panel.
1.  Place  brew  funnels  into  rails  on  both  sides  of 
brewer.
2.  Place a Soft Heat server beneath each brew fun-
nel.
3.  Press and hold the upper right hidden switch until 
display reads UNITS. Release the switch. Continue 
to press and release switch until SERVICE TOOLS 
appears. 
4.  Press YES to run tests on various components 
and outputs within the brewer. (Pressing NO will 
exit this function and advance to the next function 
screen.) 
5.  The display should read TEST OUTPUTS.
6.  In TEST OUTPUTS screen, press NO.  This advances 
to TEST SWITCHES.
7.  Pressing  NO  in  this  screen  will  advance  to  the   
next function. Press YES in the TEST SWITCHES 
screen to test the switches. The display will read 
NOTHING PRESSED.
8.  From this screen, press any of the switches on the 
Procedure to test components (outputs):
1.  Place  brew  funnels  into  rails  on  both  sides  of 
brewer.
2.  Place a Soft Heat server beneath each brew fun-
nel.
3.  Press and hold the upper right hidden switch until 
display reads UNITS. Release the switch. Continue 
to press and release switch until SERVICE TOOLS 
appears. 
4.  Press YES to run tests on various components 
and outputs within the brewer. Pressing NO will 
exit  this  function  and  advance  to  next  function 
screen.
5.  The display should read TEST OUTPUTS.
6.  Press and release YES. The display should read 
LEFT BREW VALVE.
7.  To test LEFT BREW VALVE, press ON. If the brew 
valve is functional, water should run from the left 
brew side.
8.  Press OFF to end flow of water.
9.  Press NEXT to advance to the next component to 
be tested.
NOTE: To bypass testing any component, press NEXT 
to advance to the next one, without testing the previ-
ous component.
10. To  test  LEFT  BREW  BYPASS,  press  ON.  If  the 
bypass valve is functional, water should run from 
the left brew bypass.
11. Press OFF to end flow of water.
12. Press NEXT to advance to the next component to 
be tested.
13. To test LEFT FUNNEL LOCK, press ON. If the fun-
nel lock is functional, the lock will come down to 
hold the funnel in place.
14. Press OFF to retract the funnel lock.
15. Press NEXT to advance to the next component to 
be tested.
16. To test LEFT SERVER, press ON. If the server and 
the sensor are functional, the light on the lower 
right corner of the server will illuminate.
17. Press OFF to end testing of server.
18. Press NEXT to advance to the next component to 
be tested.
19. Follow steps 7 through 15 to test the right side 
components.
20. To test REFILL VALVE, press ON. If the refill valve 
PROGRAMMING THE BREWER (cont.)
29877-3 062005