SERVICE (cont.)
 
b) 208 volts ac for three wire 120/208 volt models.
 
c) 240 volts ac for three wire 120/240 volt models.
 
d) 230 volts ac for two wire 230 volt models.
5.  Disconnect the dispenser from the power source.
If voltage is present as described the control thermostat 
is operating properly. Reinstall bulb into the tank.
If voltage is not present as described, replace the ther-
mostat.
Removal and Replacement.
1.  Remove  the  thermostat  capillary  bulb  by  firmly 
pulling-up on the capillary at the tank lid. This will 
disengage the grommet from the tank lid.
2.  Loosen the two #6-32 screws securing the thermostat 
to the front tank mounting bracket.
3.  Disconnect the wires from the thermostat.
4.   Remove  thermostat  and  remove  the  screws  and 
spacers from the thermostat.
5.  Discard thermostat.
6.  Install two spacers and two #6-32 screws on the 
new thermostat. 
7.  Position the thermostat on the botttom side of the 
front  tank  mounting  bracket  and  tighten  the  two 
#6-32 screws. 
8.  Slide the grommet to the line 4.5” above the bulb on 
the new capillary tube.
9.  Insert the capillary bulb through the hole in the tank 
lid and press the grommet firmly and evenly so that 
the groove in the grommet fits into the tank lid.
10. Carefully bend the capillary tube so that the tube and 
bulb inside the tank are in the vertical position and 
away from any electrical connections.
11. Refer to Fig. 11 and reconnect the wires. 
NOTE - The capillary tube must be clear of any electrical 
termination and not kinked.
CONTROL THERMOSTAT - FMD-1 & FMD-2 (cont.)
FIG. 11 THERMOSTAT TERMINALS
P1668
BLK from Limit
Thermostat
BLK from Tank
Heater Switch
CONTROL BOARD - FMD-2 ONLY
FIG. 12 CONTROL BOARD
Location:
          The Control Board is located behind the lower front 
access cover mounted on the component bracket.
Test Procedure:
Liquid Level Control Circuitry:
1.  Disconnect the dispenser from the power source.
2.   Disconnect the six pin connector from J3 of the 
control board.
3.  Check the voltage across pins 5 & 6 of  the six pin 
connector on the wiring harness with a voltmeter. 
Connect the dispenser to the power source. The 
indication must be 24 volts ac.
4.  Disconnect the dispenser from the power source.
If voltage is present as described, proceed to step 5.
If voltage is not present as described, refer to the wiring 
diagram and check the dispenser wiring harness.
5.  Reconnect the six pin connector of the wiring har-
ness to J3 of the control board.
CONTROL BOARD - FMD-2 ONLY (CONT.)
P1666