30
J1
LEVEL CONTROL BOARD AND LEVEL PROBE - 
FMD-1 ONLY
FIG. 26 LEVEL CONTROL BOARD AND PROBE
Location:
The level control board is located behind the lower 
access panel mounted on the right side of the compo-
nent bracket. 
The Level probe is located on the left center of the 
tank lid just in front of the overflow tube.
P1665
9.  Reconnect  the  plug  on  the  door  wiring  harness 
to the connector on the door interconnect wiring 
harness.
10. Install the door lower panel (5) using four #8-32  
screws.
LAMP STARTER and SOCkET (Refer to Fig. 25)
Location:
The lamp starter (6) is located inside the door assy 
(1) on the top of the door lower panel (5).
Test Procedures:
1.  Disconnect the dispenser from the power source.
2.  Disconnect the starter leads from the door wiring 
harness.
3.  Remove lamp starter from starter socket.
4.    Check  for  continuity  on  each  lead  of  the  starter 
socket.
If continuity is present as described the starter socket 
is operating properly.
If continuity is not present as described replace the  
starter socket.
5.  Remove starter (6) from starter socket.
6.  Check for continuity across the pins on the bottom 
of the starter (6).
If  continuity  is  present  as  described,  replace  the 
starter.
If  continuity  is  not  present  as  described,  starter  is 
operating properly.
Note: If continuity tests are both as described and lamp 
does not light, replace the starter.
Removal and Replacement (Refer to Fig.25):
1.  Open dispenser door assy (1)
2.  Remove the four #8-32 screws securing the door 
 
lower panel (5) to the door assy (1).
3.  Disconnect the leads on the starter socket from the  
door wiring harness.
4.  Remove lower door panel (5) and starter w/socket 
(6) as assembly.
5.  Compress the spring tabs on the socket and remove 
socket from the door bottom cover (5).
6.  Rotate  starter  90°  and  remove  from  the  starter
socket.
SERVICE (cont.)
LAMP REPLACEMENT (Refer to Fig.24)(cont.)
7.  Insert new starter (6) into socket and turn 90° until
the pins snap in place.
8.  Install new socket by compressing spring tabs on 
the socket and pushing the socket up through the 
hole in the lower door panel (5) and releasing spring 
tabs.
9.  Connect the sockets leads to the door wiring har-
ness.
10. Install  door  lower  panel    (5)  with  starter  and 
starter socket  on door assy (1) using four #8-32 
screws.   
29112 101598