SOLENOID VALVE (COLD WATER 
OPTIONAL)(FMD-2 ONLY)
6.  Check the solenoid valve for coil action. Connect the 
dispenser to the power source. With the cold jumper 
plug  installed  press  the  left  dispense  switch  and 
listen carefully in the vicinity of the solenoid valve 
for a “clicking” sound as the magnet attracts.
7.  Disconnect the dispenser from the power source.
If the sound is heard as described and water will not pass 
through the solenoid valve, there may be a blockage in 
the water line before the solenoid valve or, the solenoid 
valve may require inspection for wear, and removal of 
waterborne particles.
If  the  sound  is  not  heard  as  described,  replace  the 
solenoid valve.
Removal and Replacement:
1.  Loosen  the  two  screws  securing  the  component 
bracket to the dispenser base. Lift the component 
bracket off of the base and move to the right.
2.  Remove the white and blue from the solenoid
 
valve.
3.  Turn-off the water supply to the dispenser.
4.  Disconnect the water lines to and from the solenoid 
valve.
5.  Loosen the two #8-32 screws and washers securing 
the solenoid mounting bracket to the base. Remove 
solenoid bracket and solenoid valve as an assem-
bly.
6.  Remove the two #10-32 screws and lockwashers se-
curing the solenoid valve to the solenoid bracket.
7.  Using two #10-32 screws and lockwashers install new  
solenoid valve on solenoid mounting bracket.
8.  Install the solenoid valve and bracket on the dispenser 
base and tighten the two #8-32 screws.  
9.  Securely  fasten  the  water  lines  to  and  from  the 
solenoid valve.
10. Refer to Fig. 35 when reconnecting the wires.
SERVICE (cont.)
FIG. 34 COLD WATER SOLENOID VALVE
P1666
Location:
 
The cold water solenoid valve is located on the 
left side of the dispenser base just behind the compo-
nent bracket.
Test Procedures:
1.   Disconnect  the  dispenser  from  the  power 
source.
2.  Disconnect  the  white  and  blue  wires  from  the 
solenoid valve. With the cold jumper plug installed 
press  the    left  dispense  switch  on  front  of  the 
door.
3.  Check the voltage across the white and blue wires 
with  a  voltmeter.  Connect  the  dispenser  to  the 
power source. The indication must be:
 
a) 120 volts ac for two wire 120 volt models,
 
b)  120  volts  ac  for  three  wire  120/208  volt  or 
120/240 volt models,
 
c) 230 volts ac for two wire 230 volt models, after 
a delay of approximately 5 seconds.
4.  Disconnect  the  dispenser    from  the  power 
source.
If voltage is present as described, proceed to #5
If voltage is not present as described, refer to wiring 
diagram and check dispenser wiring harness.
5.  Check for continuity across the solenoid valve coil 
terminals.
If  continuity  is  present  as  described,  reconnect  the 
white and blue wires to the solenoid.
If continuity is not present as described, replace the 
solenoid valve.
FIG. 35 COLD WATER SOLENOID TERMINALS
P1215
BLU to Main Harness
WHI to Main Wiring
Harness