Bunn FMD-4 User Guide

Page of 46
20
6.  Disconnect the four pin connector from J4 of control 
board #1.
7.   Check the voltage across pins 1 & 4 of  the four pin 
connector on the wiring harness with a voltmeter. 
Connect the dispenser to the power source. The 
indication must be 120 volts ac for two wire 120 
volt models, three wire 120/208 volt models, three 
wire 120/240 volt models, or 230 volts ac for two 
wire 230 volt models.
8.   Disconnect the dispenser from the power source.
If voltage is present as described, proceed to step 9.
If voltage is not present as described, refer to the wiring 
diagram and check the dispenser wiring harness.
9.  Reconnect  the four pin connector of the wiring 
harness to J4 of control board #1.
10. Disconnect the ten pin connector from J2 of control 
board #1.
11. Carefully connect a piece of insulated jumper wire 
to pin 10 (top right) of J2 on the control board. 
Keep the other end of this wire away from any metal
surfaces of the dispenser.
12.  Check  the  voltage  across  the  terminals  of  the 
inlet solenoid valve with a voltmeter. Connect the 
dispenser  to  the  power  source.  The  indication 
must again be 120 volts ac for two wire 120 volt 
models, three wire 120/208 volt models, three wire 
120/240 volt models, or 230 volts ac for two wire 
230 volt models after a delay of approximately 10 
seconds.
13. Touch the free end of the jumper wire to the dis-
penser housing. The indication must be 0.
14. Move the jumper wire away from the housing.  The 
indication must again be 120 volts ac for two wire 
120 volt models, three wire 120/208 volt models, 
three wire 120/240 volt models, or 230 volts ac 
for two wire 230 volt models after a delay of ap-
proximately 5 seconds.
15. Disconnect the dispenser from the power source 
and remove the jumper wire.
If  voltage  is  present  as  described,  proceed  to  step 
16.
If  the  voltage  is  not  present  as  described,  replace 
control board #1.
SERVICE (cont.)
CONTROL BOARD
FIG. 11 CONTROL BOARD
Location:
 
The Control Boards are located behind the lower front 
access cover mounted on the component bracket.
Test Procedure:
Liquid Level Control Circuitry(Control Board #1):
1.  Disconnect the dispenser from the power source.
2.   Disconnect the six pin connector from J3 of the 
control board.
3.  Check the voltage across pins 5 & 6 of  the six pin 
connector on the wiring harness with a voltmeter. 
Connect the dispenser to the power source. The 
indication must be 24 volts ac.
4.  Disconnect the dispenser from the power source.
If voltage is present as described, proceed to step 5.
If voltage is not present as described, refer to the wiring 
diagram and check the dispenser wiring harness.
5.  Reconnect the six pin connector of the wiring har-
ness to J3 of the control board.