Bunn FMD-4 User Guide

Page of 46
15
SERVICE (cont.)
RED to BRN/WHI from
Control Board #1 J3-3
RED to WHI/RED from
Control Board #1 J3-2
RED to WHI/ORN from
Control Board #1 J3-1
RED to WHI/YEL from
Control Board #2 J3-3
BLK to GRN from
Control Board J3-4
P1639
FIG. 3 AUGER MOTOR TERMINALS
FIG. 4  AUGER DRIVE COMPONENTS
Location
 
The  auger  components  are  located  inside  the 
bottom part of the hopper except for the auger drive 
bracket, washer and locknut, which are located on the 
outside bottom rear of the hopper. The auger motors 
are located on the rear of the auger motor mounting 
panel. Refer to Fig. 5 for disassembly and assembly.
Test Procedures - Auger motors 
1.  Disconnect  the  dispenser  from  the  power 
source.
2.  Disconnect the wires from the motor to be test-
ed.
3.  Check the voltage across the positive (white/or-
ange)  wire  for  the  right  motor,  or  the  positive 
(white/red) wire for the left motor and the negative 
(green) wire with a voltmeter. With the rinse/run 
switch in the run (lower) position press and hold the 
appropriate dispense switch. Connect the dispenser 
to the power supply.  After a .6 second delay the 
indication must be 4.0 to 24.5 volts dc.
AUGER DRIVE COMPONENTS - FMD-4 & FMD-5
P2635
AUGER DRIVE COMPONENTS - FMD-4 (cont.)
Auger Drive  Motor (Refer to Fig. 2)
1.  Remove hopper assy (15), and set aside for reas-
sembly.
2.  Remove the four #8-32 screws securing the hopper 
support plate (11), remove plate and set aside for 
reassembly.
3.  Remove the four #8-32 screws, located inside the 
dispenser housing on the lower right front of the 
auger motor mounting panel (19), securing auger 
motor  mounting  bracket  (16)  and  auger  motor 
(17) to the rear of the auger motor mounting panel 
(19). 
4.  Disconnect  the  wires  from  the  hopper  drive 
board.
5.  Remove auger motor mounting bracket (16), auger 
motor (17) and dust seal (18) as an assembly.
6.  Remove dust seal (18) from auger motor (17).
7.  Disconnect the wires from the auger motor (17).
8.  Remove the four #8-32 screws securing the  auger 
motor (17) to the auger motor mounting bracket 
(16). 
9.  Remove auger motor (17) and discard.
10. Using four #8-32 screws install new auger motor 
(17) on mounting bracket (16).
11. Install dust seal (18) on auger motor shaft and 
align notch in seal with motor casting.
12. Reconnect the wires to the terminals on the hopper 
drive board.
13. Refer to Fig. 3 when reconnecting wires.   
14. Using four #8-32 locking screws install auger mo-
tor, dust seal and mounting bracket to the rear of 
the auger motor mounting panel (19).
15.  Install hopper assy (15).
STATIONS 1 - 4
35135 012103