Bunn H5M User Guide

Page of 20
11
SERVICE (cont.)
Safety Overflow Switch
Location:
The safety overflow switch is located inside the rear of 
the dispenser inside the copper overflow cup.
Test Procedure:
1.  Once voltage is verified at the power source, check 
for continuity across the safety overflow switch 
red wires only until the plastic float is raised and 
check that continuity returns when the plastic float 
is again lowered.
If continuity is present as described, reconnect each 
of the red wires to the black wires, the safety overflow 
switch is operating properly.
If continuity is not present as described, replace the 
safety overflow switch.
FIG. 3 SAFETY OVERFLOW SWITCH
FIG. 4 SAFETY OVERFLOW WIRING
RED to BLK Wire from 
Terminal Block
RED to BLK Wire from 
Liquid Level Board #2
P1793
P1777
Removal and Replacement:
1.  Disconnect the black wires from the safety overflow 
switch.
2.  Remove  the  nut  beneath  the  copper  overflow 
cup.
3.  Remove the entire switch assembly from the cup.
4.  Place the new switch assembly into the cup, wires 
first. Make sure that a gasket is in place around the 
threaded switch stem.
NOTE - The magnets must be at the top of the float and 
there must be NO stainless steel washers installed for 
the safety overflow switch to operate properly.
5.  Install the nut beneath the copper overflow cup.  
Be sure not to overtighten.
6.  Reconnect the wires, FIG. 4.
10267 011599