Bunn single tf brewwise dbc Operating Guide

Page of 54
Page 40
TROUBLESHOOTING
A troubleshooting guide is provided to suggest probable causes and remedies for the most likely problems 
encountered.  If  the  problem  remains  after  exhausting  the  troubleshooting  steps,  contact  the  Bunn-O-Matic 
Technical Service Department.
 
• 
Inspection, testing, and repair of electrical equipment should be performed only by qualified 
service personnel.
 
• 
All electronic components have 120 - 240 volt ac and low voltage dc potential on their terminals.  
Shorting of terminals or the application of external voltages may result in board failure.
 
• 
Intermittent operation of electronic circuit boards is unlikely.  Board failure will normally be per-
manent. If an intermittent condition is encountered, the cause will likely be a switch contact or a 
loose connection at a terminal or crimp.
 
• 
Solenoid removal requires interrupting the water supply to the valve. Damage may result if sole-
noids are energized for more than ten minutes without a supply of water.
 
• 
The use of two wrenches is recommended whenever plumbing fittings are tightened or loosened. 
This will help avoid twists and kinks in the tubing.
 
• 
Make certain that all plumbing connections are sealed and electrical connections tight and iso-
lated.
 
• 
This brewer is heated at all times. Keep away from combustibles. 
WARNING
  
• 
Exercise extreme caution when servicing electrical equipment.
  
• 
Disconnect the brewer from the power source when servicing, except when electrical tests are  
  
 
specified.
  
• 
Follow recommended service procedures.
  
• 
Replace all protective shields or safety notices.
Screen Displayed 
 
 
Possible Cause
Troubleshooting Procedures
1. 1. Overflow cup is full of water. 
This  could  be  caused  by  boiling; 
see  chart  on  page  32.  Also  could 
be Refill Sensitivity adjustment; see 
page 33.
Empty  cup.  Correct  cause  and 
retry.
1. SMART FUNNEL not fully inserted 
into the funnel rails.
2.  Not  using  a  SMART  FUNNEL
and the FUNNEL DETECT function 
is activated (on).
Position the funnel so that the sensor 
is directly beneath the sensor coil on 
the brewer.
Disable the FUNNEL DETECT func-
tion.
OVERFLOW CUP
FULL. EMPTY CUP
NO FUNNEL
PRESENT
35879.1 071405