Bunn SRU User Guide

Page of 36
Page 16
RED to Terminal
Block(L)
BLK Thermal 
Fuse to Tank 
Heater
BLK to Tank 
Heater (L1)
 
SERVICE (cont.)
CONTACTOR (cont.)
BLK to Terminal
Block (L1)
RED to Tank 
Heater (L)
BLK to Limit
Thermostat
WHI from Main Harness
(10/08V and 10/40V 
Three Wire Models)
RED from Main Harness
(08V, 40V Two Wire 
Models)
RED to Limit 
Thermostat
RED Thermal 
Fuse to Tank 
Heater
BLK to Terminal 
Block (L)
RED to Terminal 
Block (L)
BLK to Terminal 
Block (L1)
10/08V, 10/40V, 08V, 
40V MODELS
30V - CE Models
P175.50
FIG.5 CONTACTOR TERMINALS
Removal and Replacement:
1.  Disconnect all the wires from the contactor.
.  Remove  the  two  #8-3  screws  securing  the 
contactor to the contactor mounting bracket.
3.  Install new contactor and secure with two #8-3 
screws.
4.  Refer to Fig. 5 and reconnect the wires.
10067 040100