Bunn SRU User Guide
Page 16
RED to Terminal
Block(L)
BLK Thermal
Fuse to Tank
Heater
BLK to Tank
Heater (L1)
SERVICE (cont.)
CONTACTOR (cont.)
BLK to Terminal
Block (L1)
RED to Tank
Heater (L)
BLK to Limit
Thermostat
WHI from Main Harness
(10/08V and 10/40V
Three Wire Models)
RED from Main Harness
(08V, 40V Two Wire
Models)
RED to Limit
Thermostat
RED Thermal
Fuse to Tank
Heater
BLK to Terminal
Block (L)
RED to Terminal
Block (L)
BLK to Terminal
Block (L1)
10/08V, 10/40V, 08V,
40V MODELS
30V - CE Models
P175.50
FIG.5 CONTACTOR TERMINALS
Removal and Replacement:
1. Disconnect all the wires from the contactor.
. Remove the two #8-3 screws securing the
contactor to the contactor mounting bracket.
3. Install new contactor and secure with two #8-3
screws.
4. Refer to Fig. 5 and reconnect the wires.
10067 040100