FIG. 12 LIMIT THERMOSTAT
P3040
Location:
 
The limit thermostat is located inside the hood on 
the tank lid.
Test Procedure:
1.  Disconnect the brewer from the power source and 
remove the black wire from the limit thermostat.
2.  With a voltmeter, check the voltage across the 
black wire removed from the limit thermostat 
and the white wire or red wire on the tank heater 
terminal.  Connect the brewer to the power source.  
The indication must be:
 
a) 120 volts ac for two wire 120 volt models.
 
b) 230 volts ac for two wire 230 volt models.
 
c) 100 volts ac for two wire 100 volt models.
3.  Disconnect the brewer from the power source.
If voltage is present as described, reconnect the black 
wire and proceed to #4.
If voltage is not present as described, refer to the Wir-
ing Diagrams
 and check the wiring harness.
4.  Remove the blue/black wire from the limit ther-
mostat.
5.  With a voltmeter, check the voltage across the 
exposed terminal of the limit thermostat and the 
white wire from the power cord or the red wire 
from the power connector. Connect the brewer to 
the power source. The indication must be: 
 
a) 120 volts ac for two wire 120 volt models.
 
b) 230 volts ac for two wire 230 volt models.
 
c) 100 volts ac for two wire 100 volt models.
6.  Disconnect the brewer from the power source.
If voltage is present as described, reconnect the blue/
black wire to the limit thermostat.  The limit thermostat 
is operating properly.
If voltage is not present as described, replace the limit 
thermostat.
Removal and Replacement
1.  Remove both wires from the limit thermostat 
terminals.
2.  Carefully slide the limit thermostat out from under 
the retaining clip.
3.  Carefully slide the new limit thermostat into the 
retaining clip.
4.  Refer to Fig. 13 when reconnecting the wires.
BLU/BLK to
Control
Thermostat
BLK to Power Cord or
Power Connector 
FIG. 13 LIMIT THERMOSTAT TERMINALS
P1800