FIG. 22 TANK HEATER
Location:
 
The tank heater is located inside the tank and 
secured to the tank lid.
Test Procedures:
1.  Disconnect the brewer from the power supply.
2.  With a voltmeter, check the voltage across the 
black and white wires on 100 volt and 120 volt 
models or the black and red wires for 230 volt 
models. Connect the brew to the power source. 
The indication must be:
 
a) 120 volts ac for two wire 120 volt models .
 
b) 230 volts ac for two wire 230 volt models. 
c) 100  volts ac for two wire 100 volt models. 
3.  Disconnect the brewer from the power source.
If voltage is present as described, proceed to #4
If voltage is not present as described, refer to the Wir-
ing Diagrams
 and check wiring harness.
4.   Disconnect the black wire and the white wire or 
red wire from the tank heater terminals.
5.   Check for continuity across the tank heater termi-
nals.
If continuity is present as described, reconnect the 
wires, the tank heater is operating properly.
If continuity is not present as described, replace the 
tank heater.
P3040
NOTE- If the tank heater remains unable to heat, 
remove and inspect heater for cracks in the 
sheath.
Removal and Replacement:
1.   Disconnect the black wire and the white or red 
wire from the tank heater terminals.
2.  Remove sprayhead and the  hex nut securing the 
sprayhead tube to the hood.  Set aside for reas-
sembly.
3. Disconnect 
vent 
tube.
4.  Remove the six #10 thread cutting screws securing 
the tank lid to the tank.
5.   Remove the tank lid with limit thermostat, spray-
head tube, tank heater and vent tube.
6.  Remove the two hex nuts securing the tank heater 
to the tank lid. Remove tank heater with gaskets 
and discard.
7.  Install new tank heater with gaskets on the tank 
lid and secure with two hex nuts.
8.  Install tank lid with limit thermostat, sprayhead 
tube, tank heater and vent tube using six #10 
thread cutting screws.
9.  Secure sprayhead tube to hood using a  hex nut.
10. Install sprayhead.
11. Connect vent tube to fi tting.
12. Reconnect the wires to the limit thermostat, tank 
heater. See limit thermostat section in this manual 
when reconnecting wires.
13. Refer to Fig. 23 when reconnecting the tank heater 
wires. 
WHI to Power Cord (100V 
& 120V Models)
RED to Power Connector 
(230V Models)
BLK to Control 
Thermostat
37235  080204