Behringer eg2180 User Guide

Page of 30
EUROGRAND
Connection to external equipment
20
Demo song and music sequencer data are not transmit-
 
+
ted via the MIDI output. However, you can transmit a 
music piece recorded with the built-in music sequencer 
using the MIDI dump feature (see „Sending music se-
quencer data" below).
Setting the MIDI receive channel
 
>
Use  this  function  to  set  the  receive  channel  on  which  the 
EUROGRAND is to receive MIDI data. MIDI devices must transmit 
and receive on the same MIDI channels to ensure successful MIDI 
communication. Select the default setting ALL for proper operation 
in combination with a music computer.
Function: 
E7.2
Value: 
All, 1-2, 1 ... 16
Description:
All: 
Simultaneous multi-timbral reception of MIDI 
data on all 16 MIDI channels. (Default setting)
1-2: 
Reception of MIDI data on channels 1 and 2
1 ... 16: 
Reception of MIDI data on the specified MIDI 
channel
The multi-timbral reception of MIDI data allows you to 
 
+
use the EUROGRAND in combination with a sequencing 
program as a sound generator for multi-track recordings 
(see chapter 6.3.2).
Enable/disable sound generator (Local on/off)
 
>
This function allows you to determine whether the built-in sound 
generator directly plays the notes you play on the keyboard or 
whether it only responds to MIDI note information received via 
the MIDI IN jack. The latter setting is quite useful, for example, in 
sequencer mode. In a closed MIDI chain the looping through of 
MIDI signals could otherwise lead to double sounds, i.e. when you 
hit a key on the keyboard, the EUROGRAND plays the note directly 
only to play it again shortly after, when the MIDI commands sent 
to the sequencer come back via the MIDI IN of the EUROGRAND. 
When the EUROGRAND is set to Local Off, the MIDI data are only 
sent to the sequencer. The notes are played only once when the 
MIDI signals come back from the sequencer.
Function: 
E7.3
Value: 
On, Off
Description:
On:  
Sound generator responds to keyboard and 
MIDI notes (default setting)
Off:  
Sound generator does not respond to the key-
board but to MIDI notes only
Accept/ignore program changes
 
>
Use this function to determine how the EUROGRAND responds 
to  MIDI  program  change  commands.  These  commands  are 
used, for example, to select sounds of the EUROGRAND using 
MIDI commands sent from a sequencing program. Conversely, 
program change commands can be sent via the MIDI output of 
the EUROGRAND whenever you select a sound in the SOUND 
SELECT section (see chapter 9.2).
Function: 
E7.4
Value: 
On, Off
Description:   
On: 
Program change commands are sent and 
received (default setting)
Off:  
Program change commands are neither sent 
nor received
Accept/ignore MIDI controller information
 
>
Use this function to determine how the EUROGRAND responds 
to MIDI controller data. MIDI uses a variety of controller informai-
ton to control sound changes (e.g. pedal status, volume, effect 
intensity).
Function: 
E7.5
Value: 
On, Off
Description:
On:  
Controller data are sent and received (default 
setting)
Off:  
Controller data are neither sent nor received
The  EUROGRAND  only  responds  to  the  commands 
 
+
listed in the MIDI implementation chart if controller data 
are enabled (see chapter 9.4).
MIDI transposition
 
>
This  function  determines  whether  outgoing  MIDI  data  are 
transposed  independently  of  the  built-in  sound  generator. This 
can be useful to play the sounds of an external sound module 
whose sound generator is controlled from the keyboard of the 
EUROGRAND in a different pitch than the internal sounds of the 
EUROGRAND.
Function: 
E7.6
Value: 
-12 ... 12
Description:
0: 
No transposition of the pitch at the MIDI output 
(default setting)
1 ...12: 
Pitch is transposed up by the number of half-
tones selected
-1 ... -12: 
Pitch is transposed down by the number of half-
tones selected
This setting has no effect on the sound generator of 
 
+
the EUROGRAND.
Send control panel settings (snapshot)
 
>
Use  this  function  to  transmit  the  current  settings  of  the 
EUROGRAND  (e.g.  sounds  and  effects,  channel  volume)  via 
the MIDI output. This type of transmission only includes system-
exclusive data packages (MIDI dump).
Function: 
E7.7
Value: 
-
Description:
Connect  the  EUROGRAND  to  a  computer  or  hardware 
1) 
sequencer as described in chapter 6.3.2.
Set the MIDI sequencer to reception-ready mode.
2) 
Select the function 
3) 
E7.7
 in EDIT mode.
Press the +/YES button to execute the transmission.
4) 
When the transmission is complete, the display shows End.
You can send the data back to the EUROGRAND at a 
 
+
later date. To do this, use the MIDI IN jack to connect 
the EUROGRAND to the device that received the data 
before. As soon as you start the transmission from the 
MIDI  sequencer,  the  EUROGRAND  will  automatically 
receive the data. Make sure that neither DEMO, EDIT or 
music sequencer mode is active!