Cma -66l Quick Setup Guide

Page of 2
ELECTRICAL
CONNECTION
CMA-44
REAR VIEW
1-2008
CMA-44/66 
Quick Setup 
Instructions
3
PRESSURE
REGULATOR
OPTIONAL VENT
HOODS 4"X16"
2
STEP
1
STEP
3
STEP
VOLTS  
PHASE
AMPS
208
1
61
240
1
65
208
3
38
240      
3
42
          HEATER      10kW
ELECTRICAL
HARD WIRE
CONNECTION
POINT
3/4" WATER
INLET
2
1/2" WATER
INLET
1
1
DRAIN PIPE
4
DETERGENT 
FITTING INLET
5
MIXING
CHAMBER
5
SCRAP
TRAP DRAIN
4
Connect hot water supply line to rinse 1/2"water
inlet. Adjust pressure regulator if necessary. Water 
temperature should be 140
°F wash and 140°F rinse 
for CMA-44L. The CMA-44H should read 155
°F wash, 
180
°F rinse.
Connect fill water supply line (120
°F/140°F) to a
3 / 4 " w a t e r   i n l e t   t o   f i l l   t h e   m a c h i n e .
Connect drain at either end of the horizontal
drain pipe from wash tank or scrap trap drain.
3 Phase: Connect the wire with the highest voltage
(stinger lead) to L2 on the contactor. L1, L2 and L3
must comply with all local and state electrical codes
for sizing of wire and circuit breaker protection.
Additional information can be found in the Installation
and Operation manual supplied with machine.
DRAIN PLUMBING 
NOT SUPPLIED
2" HOLE 
PLUG
Remove plastic plug to install detergent fitting. Remove 
plug from the mixing chamber to install sani/rinse injection 
fitting (sanitizer detergent and rinse injection fittings provided 
by dispenser manufacturer, CMA does not supply.) 
WARNING
: Electrical and plumbing
connections need to be made by a
licensed service person and comply
with all Federal, State and Local 
Health, Electrical, Plumbing and 
Safety codes.
800-854-6417